SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:su-135179"
 

Search: onr:"swepub:oai:DiVA.org:su-135179" > Deconvolution of So...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Deconvolution of Soft Ionization Mass Spectra of Chlorinated Paraffins To Resolve Congener Groups

Yuan, Bo (author)
Stockholms universitet,Institutionen för miljövetenskap och analytisk kemi
Alsberg, Tomas (author)
Stockholms universitet,Institutionen för miljövetenskap och analytisk kemi
Bogdal, Christian (author)
show more...
MacLeod, Matthew (author)
Stockholms universitet,Institutionen för miljövetenskap och analytisk kemi
Berger, Urs (author)
Gao, Wei (author)
Wang, Yawei (author)
de Wit, Cynthia A. (author)
Stockholms universitet,Institutionen för miljövetenskap och analytisk kemi
show less...
 (creator_code:org_t)
2016-09-07
2016
English.
In: Analytical Chemistry. - : American Chemical Society (ACS). - 0003-2700 .- 1520-6882. ; 88:18, s. 8980-8988
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • We describe and illustrate a three-step data-processing approach that enables individual congener groups of chlorinated-paraffins (CPs) to be resolved in mass spectra obtained from either-of two soft ionization methods: electron capture negative-ionization mass spectrometry (ECNI-MS) or atmospheric pressure chemical ionization mass spectrometry (APCI-MS). In the first step, general fragmentation pathways of CPs are deduced from analysis of mass spectra of individual CP congeners. In the-Second step, all possible fragment ions in the general fragmentation pathways of CPs with 10 to 20 carbon atoms are enumerated and compared to mass spectra of CP mixture standards, and a deconvolution algorithm is applied to identify fragment ions that are actually observed. In the third step, isotope permutations of the observed fragment ions are calculated and used to identify isobaric overlaps, so that mass intensities of indivichial CP congener groups can be deconvolved from the unresolved isobaric ion signal intensities in mass spectra. For a specific instrument; the three steps only need to be done once to enable deconvolution of CPs in unknown samples. This approach enables congener group-level resolution of CP mixtures in environmental samples, and: it opens up the possibility, for quantification of congener group.

Subject headings

NATURVETENSKAP  -- Kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences (hsv//eng)

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view