Search: onr:"swepub:oai:DiVA.org:su-139929" > Defining the hypoxi...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 05226naa a2200517 4500 | |
001 | oai:DiVA.org:su-139929 | |
003 | SwePub | |
008 | 170220s2017 | |||||||||||000 ||eng| | |
009 | oai:DiVA.org:uu-396691 | |
009 | oai:prod.swepub.kib.ki.se:135789202 | |
009 | oai:DiVA.org:liu-134640 | |
024 | 7 | a https://urn.kb.se/resolve?urn=urn:nbn:se:su:diva-1399292 URI |
024 | 7 | a https://doi.org/10.1080/0284186X.2017.12932892 DOI |
024 | 7 | a https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-3966912 URI |
024 | 7 | a http://kipublications.ki.se/Default.aspx?queryparsed=id:1357892022 URI |
024 | 7 | a https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-1346402 URI |
040 | a (SwePub)sud (SwePub)uud (SwePub)kid (SwePub)liu | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a ref2 swepub-contenttype |
072 | 7 | a art2 swepub-publicationtype |
100 | 1 | a Lindblom, Emelyu Stockholms universitet,Fysikum,Stockholm University, Sweden4 aut0 (Swepub:su)emli3946 |
245 | 1 0 | a Defining the hypoxic target volume based on positron emission tomography for image guided radiotherapy – the influence of the choice of the reference region and conversion function |
264 | 1 | a Oxfordshire :b Taylor & Francis,c 2017 |
338 | a print2 rdacarrier | |
500 | a Funding agencies: European Union; Cancer Research Foundations of Radiumhemmet | |
520 | a Background: Hypoxia imaged by positron emission tomography (PET) is a potential target for optimization in radiotherapy. However, the implementation of this approach with respect to the conversion of intensities in the images into oxygenation and radiosensitivity maps is not straightforward. This study investigated the feasibility of applying two conversion approaches previously derived for 18F-labeled fluoromisonidazole (18F-FMISO)-PET images for the hypoxia tracer 18F-flortanidazole (18F-HX4).Material and methods: Ten non-small-cell lung cancer patients imaged with 18F-HX4 before the start of radiotherapy were considered in this study. PET image uptake was normalized to a well-oxygenated reference region and subsequently linear and non-linear conversions were used to determine tissue oxygenations maps. These were subsequently used to delineate hypoxic volumes based partial oxygen pressure (pO2) thresholds. The results were compared to hypoxic volumes segmented using a tissue-to-background ratio of 1.4 for 18F-HX4 uptake.Results: While the linear conversion function was not found to result in realistic oxygenation maps, the non-linear function resulted in reasonably sized sub-volumes in good agreement with uptake-based segmented volumes for a limited range of pO2 thresholds. However, the pO2 values corresponding to this range were significantly higher than what is normally considered as hypoxia. The similarity in size, shape, and relative location between uptake-based sub-volumes and volumes based on the conversion to pO2 suggests that the relationship between uptake and pO2 is similar for 18F-FMISO and 18F-HX4, but that the model parameters need to be adjusted for the latter.Conclusions: A non-linear conversion function between uptake and oxygen partial pressure for 18F-FMISO-PET could be applied to 18F-HX4 images to delineate hypoxic sub-volumes of similar size, shape, and relative location as based directly on the uptake. In order to apply the model for e.g., dose-painting, new parameters need to be derived for the accurate calculation of dose-modifying factors for this tracer. | |
650 | 7 | a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Cancer och onkologi0 (SwePub)302032 hsv//swe |
650 | 7 | a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Cancer and Oncology0 (SwePub)302032 hsv//eng |
653 | a medicinsk strålningsfysik | |
653 | a Medical Radiation Physics | |
700 | 1 | a Dasu, Alexandruu Linköpings universitet,Avdelningen för radiologiska vetenskaper,Medicinska fakulteten,The Skandion Clinic, Uppsala, Sweden4 aut0 (Swepub:liu)aleda92 |
700 | 1 | a Uhrdin, Johanu RaySearch Laboratories AB, Sweden4 aut |
700 | 1 | a Even, Aniek J. G.u Maastricht University Medical Center, Maastricht, The Netherlands4 aut |
700 | 1 | a van Elmpt, Wouteru Maastricht University Medical Center, Maastricht, The Netherlands4 aut |
700 | 1 | a Lambin, Philippeu Maastricht University Medical Center, Maastricht, The Netherlands4 aut |
700 | 1 | a Wersäll, Peteru Karolinska Institutet,Karolinska University Hospital, Stockholm, Sweden4 aut |
700 | 1 | a Toma-Dasu, Iulianau Karolinska Institutet,Stockholms universitet,Fysikum,Stockholm University and Karolinska Institutet, Sweden4 aut0 (Swepub:su)iuda0736 |
710 | 2 | a Stockholms universitetb Fysikum4 org |
773 | 0 | t Acta Oncologicad Oxfordshire : Taylor & Francisg 56:6, s. 819-825q 56:6<819-825x 0284-186Xx 1651-226X |
856 | 4 | u https://doi.org/10.1080/0284186X.2017.1293289y Fulltext |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:su:diva-139929 |
856 | 4 8 | u https://doi.org/10.1080/0284186X.2017.1293289 |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-396691 |
856 | 4 8 | u http://kipublications.ki.se/Default.aspx?queryparsed=id:135789202 |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-134640 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.
Copy and save the link in order to return to this view