SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:su-140237"
 

Search: onr:"swepub:oai:DiVA.org:su-140237" > Investigation of th...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Investigation of the influence of calibration practices on cytogenetic laboratory performance for dose estimation

Trompier, Francois (author)
Baumann, Marion (author)
Barrios, Lleonard (author)
show more...
Gregoire, Eric (author)
Abend, Michael (author)
Ainsbury, Elizabeth (author)
Barnard, Stephen (author)
Barquinero, Joan Francesc (author)
Antonio Bautista, Juan (author)
Brzozowska, Beata (author)
Stockholms universitet,Institutionen för molekylär biovetenskap, Wenner-Grens institut
Perez-Calatayud, Jose (author)
De Angelis, Cinzia (author)
Dominguez, Inmaculada (author)
Hadjidekova, Valeria (author)
Kulka, Ulrike (author)
Carlos Mateos, Juan (author)
Meschini, Roberta (author)
Gil, Octavia Monteiro (author)
Moquet, Jayne (author)
Oestreicher, Ursula (author)
Montoro Pastor, Alegria (author)
Quintens, Roel (author)
Sebastia, Natividad (author)
Sommer, Sylwester (author)
Stoyanov, Orlin (author)
Thierens, Hubert (author)
Terzoudi, Georgia (author)
Ignacio Villaescusa, Juan (author)
Vral, Anne (author)
Wojcik, Andrzej (author)
Stockholms universitet,Institutionen för molekylär biovetenskap, Wenner-Grens institut
Zafiropoulos, Demetre (author)
Roy, Laurence (author)
show less...
 (creator_code:org_t)
2016-10-13
2017
English.
In: International Journal of Radiation Biology. - : Informa UK Limited. - 0955-3002 .- 1362-3095. ; 93:1, s. 118-126
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Purpose: In the frame of the QA program of RENEB, an inter-laboratory comparison (ILC) of calibration sources used in biological dosimetry was achieved to investigate the influence of calibration practices and protocols on the results of the dose estimation performance as a first step to harmonization and standardization of dosimetry and irradiation practices in the European biological dosimetry network. Materials and methods: Delivered doses by irradiation facilities used by RENEB partners were determined with EPR/alanine dosimetry system. Dosimeters were irradiated in the same conditions as blood samples. A short survey was also performed to collect the information needed for the data analysis and evaluate the diversity of practices. Results: For most of partners the deviation of delivered dose from the targeted dose remains below 10%. Deviations larger than 10% were observed for five facilities out of 21. Origins of the largest discrepancies were identified. Correction actions were evaluated as satisfactory. The re-evaluation of some ILC results for the fluorescence in situ hybridization (FISH) and premature chromosome condensation (PCC) assays has been performed leading to an improvement of the overall performances. Conclusions: This work has shown the importance of dosimetry in radiobiology studies and the needs of harmonization, standardization in irradiation and dosimetry practices and educational training for biologists using ionizing radiation.

Subject headings

NATURVETENSKAP  -- Biologi (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Maskinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

Alanine dosimetry
biological dosimetry
calibration
inter-laboratory comparison
quality assurance

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library