Consistency in reference radiotherapy dosimetry : resolution of an apparent conundrum when Co-60 is the reference quality for charged-particle and photon beams

Andreo, Pedro (author)
Karolinska Institutet,Stockholms universitet,Fysikum
Wulff, Joerg (author)
Burns, David T. (author)
show more...
Palmans, Hugo (author)
show less...
 (creator_code:org_t)
2013-09-09
2013
English.
In: Physics in Medicine and Biology. - : IOP Publishing. - 0031-9155 .- 1361-6560. ; 58:19, s. 6593-6621
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Substantial changes in ion chamber perturbation correction factors in Co-60 gamma-rays, suggested by recent Monte Carlo (MC) calculations, would cause a decrease of about 1.5% in the reference dosimetry of all types of charged particles (electrons, protons and heavier ions) based on calculated k(Q) values. It has gone largely unnoticed that the ratio of calibration coefficients N-D,N-w,N-Co60 and N-K,N-air,N-Co60 yields an experimental value of F-ch,F-Co60 = (s(w-air) pch)(Co60) through N-D,N-air,N-Co60. Coefficients provided by the IAEA and traceable to the BIPM for 91 NE-2571 chambers result in an average F-ch,F-Co60 which is compared with published (and new) MC simulations and with the value in IAEA TRS-398. It is shown that TRS-398 agrees within 0.12% with the experimental F-ch,F-Co60. The 1.5% difference resulting from MC calculations (1.1% for the new simulations) cannot be justified using current fundamental data and BIPM standards if consistency in the entire dosimetry chain is sought. For photons, MC k(Q) factors are compared with TRS-398. Using the same uncertainty for W-air, the two sets of data overlap considerably. Experimental k(Q) values from standards laboratories lie between the two sets of calculated values, showing no preference for one set over the other. Observed chamber-to-chamber differences, that include the effect of waterproof sleeves (also seen for Co-60), justify the recommendation in TRS-398 for k(Q) values specifically measured for the user chamber. Current developments on I-values for the stopping powers of water and graphite are presented. A weighted average I-water = 78 +/- 2 eV is obtained from published experimental and DRF-based values; this would decrease sw-air for all types of radiotherapy beams between 0.3% and 0.6%, and would consequently decrease the MC derived F-ch,F-Co60. The implications of a recent proposal for I-graphite = 81 eV are analysed, resulting in a potential decrease of 0.7% in N-K,N-air,N-Co60 which would raise the experimental F-ch,F-Co60; this would result in an increase of about 0.8% in the current TRS-398 value when referred to the BIPM standards. MC derived F-ch,F-Co60 using new stopping powers would then agree at a level of 0.1% with the experimental value, confirming the need for consistency in the dosimetry chain data. Should world average standards be used as reference, the figures would become +0.4% for TRS-398 and -0.3% for the MC calculation. F-ch,F-Q calculated for megavoltage photons using new stopping powers would decrease by between 0.2% and 0.5%. When they enter as a ratios in k(Q), differences with MC values based on current key data would be within 0.2% but their discrepancy with k(Q) experimental photon values remains unresolved. For protons the new data would require an increase in W-air,W-Q of about 0.6%, as this is inferred from a combination of calorimetry and ionometry. This consistent scenario would leave unchanged the current TRS-398 k(Q) (NE-2571) data for protons, as well as for ions heavier than protons unless new independent W-air,W-Q values become available. Also in these advanced radiotherapy modalities, the need for maintaining data consistency in an analysis that unavoidably must include the complete dosimetry chain is demonstrated.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomedicinsk laboratorievetenskap/teknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomedical Laboratory Science/Technology (hsv//eng)

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Andreo, Pedro
Wulff, Joerg
Burns, David T.
Palmans, Hugo
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Medical Biotechn ...
and Biomedical Labor ...
Articles in the publication
Physics in Medic ...
By the university
Stockholm University
Karolinska Institutet

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view