SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:su-95076"
 

Search: onr:"swepub:oai:DiVA.org:su-95076" > Automated clean-up,...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Automated clean-up, separation and detection of polycyclic aromatic hydrocarbons in particulate matter extracts from urban dust and diesel standard reference materials using a 2D-LC/2D-GC system

Ahmed, Trifa M. (author)
Stockholms universitet,Institutionen för analytisk kemi
Lim, Hwanmi (author)
Stockholms universitet,Institutionen för analytisk kemi
Bergvall, Christoffer (author)
Stockholms universitet,Institutionen för analytisk kemi
show more...
Westerholm, Roger (author)
Stockholms universitet,Institutionen för analytisk kemi
show less...
 (creator_code:org_t)
2013-07-28
2013
English.
In: Analytical and Bioanalytical Chemistry. - : Springer Science and Business Media LLC. - 1618-2642 .- 1618-2650. ; 405:25, s. 8215-8222
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • A multidimensional, on-line coupled liquid chromatographic/gas chromatographic system was developed for the quantification of polycyclic aromatic hydrocarbons (PAHs). A two-dimensional liquid chromatographic system (2D-liquid chromatography (LC)), with three columns having different selectivities, was connected on-line to a two-dimensional gas chromatographic system (2D-gas chromatography (GC)). Samples were cleaned up by combining normal elution and column back-flush of the LC columns to selectively remove matrix constituents and isolate well-defined, PAH enriched fractions. Using this system, the sequential removal of polar, mono/diaromatic, olefinic and alkane compounds from crude extracts was achieved. The LC/GC coupling was performed using a fused silica transfer line into a programmable temperature vaporizer (PTV) GC injector. Using the PTV in the solvent vent mode, excess solvent was removed and the enriched PAH sample extract was injected into the GC. The 2D-GC setup consisted of two capillary columns with different stationary phase selectivities. Heart-cutting of selected PAH compounds in the first GC column (first dimension) and transfer of these to the second GC column (second dimension) increased the baseline resolutions of closely eluting PAHs. The on-line system was validated using the standard reference materials SRM 1649a (urban dust) and SRM 1975 (diesel particulate extract). The PAH concentrations measured were comparable to the certified values and the fully automated LC/GC system performed the clean-up, separation and detection of PAHs in 16 extracts in less than 24 h. The multidimensional, on-line 2D-LC/2D-GC system eliminated manual handling of the sample extracts and minimised the risk of sample loss and contamination, while increasing accuracy and precision.

Subject headings

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Keyword

2D-GC
2D-LC
Benzo[a]pyrene
Heart cut
PAH
SRM1649a
SRM1975
Analytical Chemistry
analytisk kemi

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Ahmed, Trifa M.
Lim, Hwanmi
Bergvall, Christ ...
Westerholm, Roge ...
About the subject
NATURAL SCIENCES
NATURAL SCIENCES
and Chemical Science ...
and Analytical Chemi ...
Articles in the publication
Analytical and B ...
By the university
Stockholm University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view