Sökning: onr:"swepub:oai:DiVA.org:umu-117804" >
The accuracy of qua...
The accuracy of quantitative parameters in Tc-99m-MAG3 dynamic renography : a national audit based on virtual image data
-
- Brolin, Gustav (författare)
- Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Lund University, Sweden
-
- Edenbrandt, Lars (författare)
- Lund University,Lunds universitet,Nuklearmedicin, Malmö,Forskargrupper vid Lunds universitet,Nuclear medicine, Malmö,Lund University Research Groups,EQUALIS AB, Sweden; Lund University, Sweden
-
- Granerus, Göran (författare)
- Linköpings universitet,Avdelningen för kardiovaskulär medicin,Hälsouniversitetet,Region Östergötland, Fysiologiska kliniken US
-
visa fler...
-
- Olsson, Anna (författare)
- Linköpings universitet,Medicinska fakulteten,Avdelningen för radiologiska vetenskaper
-
- Afzelius, David (författare)
- EQUALIS AB, Sweden
-
- Gustafsson, Agneta (författare)
- EQUALIS AB, Sweden; Karolinska University Hospital, Sweden
-
- Jonsson, Cathrine (författare)
- EQUALIS AB, Sweden; Karolinska University Hospital, Sweden
-
- Hagerman, Jessica (författare)
- EQUALIS AB, Sweden; Skåne University Hospital, Sweden
-
- Johansson, Lena (författare)
- EQUALIS AB, Sweden; Central Hospital Karlstad, Sweden
-
- Riklund, Katrine (författare)
- Umeå universitet,Diagnostisk radiologi,EQUALIS AB, Uppsala, Sweden,EQUALIS AB, Sweden; Umeå University, Sweden
-
- Ljungberg, Michael (författare)
- Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Lund University, Sweden
-
visa färre...
-
(creator_code:org_t)
- 2014-10-28
- 2016
- Engelska.
-
Ingår i: Clinical Physiology and Functional Imaging. - : Wiley. - 1475-0961 .- 1475-097X. ; 36:2, s. 146-154
- Relaterad länk:
-
http://www.ncbi.nlm....
-
visa fler...
-
http://dx.doi.org/10...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
https://lup.lub.lu.s...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- Assessment of image analysis methods and computer software used in Tc-99m-MAG3 dynamic renography is important to ensure reliable study results and ultimately the best possible care for patients. In this work, we present a national multicentre study of the quantification accuracy in Tc-99m-MAG3 renography, utilizing virtual dynamic scintigraphic data obtained by Monte Carlo-simulated scintillation camera imaging of digital phantoms with time-varying activity distributions. Three digital phantom studies were distributed to the participating departments, and quantitative evaluation was performed with standard clinical software according to local routines. The differential renal function (DRF) and time to maximum renal activity (T-max) were reported by 21 of the 28 Swedish departments performing Tc-99m-MAG3 studies as of 2012. The reported DRF estimates showed a significantly lower precision for the phantom with impaired renal uptake than for the phantom with normal uptake. The T-max estimates showed a similar trend, but the difference was only significant for the right kidney. There was a significant bias in the measured DRF for all phantoms caused by different positions of the left and right kidney in the anterior-posterior direction. In conclusion, this study shows that virtual scintigraphic studies are applicable for quality assurance and that there is a considerable uncertainty associated with standard quantitative parameters in dynamic Tc-99m-MAG3 renography, especially for patients with impaired renal function.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering -- Medical Image Processing (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Basic Medicine -- Physiology (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine (hsv//eng)
Nyckelord
- Tc-99m-MAG3
- differential renal function
- digital phantoms
- dynamic renography
- Monte Carlo imaging simulations
- quality assurance
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Brolin, Gustav
-
Edenbrandt, Lars
-
Granerus, Göran
-
Olsson, Anna
-
Afzelius, David
-
Gustafsson, Agne ...
-
visa fler...
-
Jonsson, Cathrin ...
-
Hagerman, Jessic ...
-
Johansson, Lena
-
Riklund, Katrine
-
Ljungberg, Micha ...
-
visa färre...
- Om ämnet
-
- TEKNIK OCH TEKNOLOGIER
-
TEKNIK OCH TEKNO ...
-
och Medicinteknik
-
och Medicinsk bildbe ...
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Medicinska och f ...
-
och Fysiologi
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Klinisk medicin
- Artiklar i publikationen
-
Clinical Physiol ...
- Av lärosätet
-
Umeå universitet
-
Lunds universitet
-
Linköpings universitet