SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:umu-120207"
 

Search: onr:"swepub:oai:DiVA.org:umu-120207" > Adverse events in a...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Mörtzell Henriksson, MonicaUmeå universitet,Medicin,Nephrol, Umeå, Sweden (author)

Adverse events in apheresis : an update of the WAA registry data

  • Article/chapterEnglish2016

Publisher, publication year, extent ...

  • Elsevier,2016
  • electronicrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:umu-120207
  • https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-120207URI
  • https://doi.org/10.1016/j.transci.2016.01.003DOI
  • https://lup.lub.lu.se/record/8577414URI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-135128URI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:for swepub-publicationtype

Notes

  • Apheresis with different procedures and devices are used for a variety of indications that may have different adverse events (AEs). The aim of this study was to clarify the extent and possible reasons of various side effects based on data from a multinational registry. The WAA-apheresis registry data focus on adverse events in a total of 50846 procedures in 7142 patients (42% women). AEs were graded as mild, moderate (need for medication), severe (interruption due to the AE) or death (due to AE). More AEs occurred during the first procedures versus subsequent (8.4 and 5.5%, respectively). AEs were mild in 2.4% (due to access 54%, device 7%, hypotension 15%, tingling 8%), moderate in 3% (tingling 58%, urticaria 15%, hypotension 10%, nausea 3%), and severe in 0.4% of procedures (syncope/hypotension 32%, urticaria 17%, chills/fever 8%, arrhythmia/asystole 4.5%, nausea/vomiting 4%). Hypotension was most common if albumin was used as the replacement fluid, and urticaria when plasma was used. Arrhythmia occurred to similar extents when using plasma or albumin as replacement. In 64% of procedures with bronchospasm, plasma was part of the replacement fluid used. Severe AEs are rare. Although most reactions are mild and moderate, several side effects may be critical for the patient. We present side effects in relation to the procedures and suggest that safety is increased by regular vital sign measurements, cardiac monitoring and by having emergency equipment nearby.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Newman, EBone Marrow Transplant and Apheresis, New South Wales, Australia (author)
  • Witt, VSt. Anna, Vienna, Austria (author)
  • Derfler, KAKH, Vienna, Austria (author)
  • Leitner, GAKH, Vienna, Austria (author)
  • Eloot, SGent, Belgium (author)
  • Dhondt, AGent, Belgium (author)
  • Deeren, DRoeselar, Belgium (author)
  • Rock, GCanada (author)
  • Ptak, JFrydek-Mistek, Czech Republic (author)
  • Blaha, MHradec Kralove, Czech Republic (author)
  • Lanska, MHradec Kralove, Czech Republic (author)
  • Gasova, ZPrague, Czech Republic (author)
  • Hrdlickova, ROstrava, Czech Republic (author)
  • Ramlow, WRostock, Germany (author)
  • Prophet, HRostock, Germany (author)
  • Liumbruno, GLivorno, Italy (author)
  • Mori, ELivorno, Italy (author)
  • Griskevicius, AVilnius, Lithuania,BC, Umeå, Sweden (author)
  • Audzijoniene, JVilnius, Lithuania (author)
  • Vrielink, HAmsterdam, The Netherlands (author)
  • Rombout, SMaastricht, The Netherlands (author)
  • Aandahl, AOslo, Norway,Skopje, Macedonia,Nephrol., Karlstad, Sweden (author)
  • Sikole, A (author)
  • Tomaz, JCoimbra, Portugal (author)
  • Lalic, KBelgrade, Serbia (author)
  • Mazic, SZagreb, Croatia (author)
  • Strineholm, VOrebro, Sweden (author)
  • Brink, BHuddinge, Sweden,Nephrol, Umeå, Sweden,Nephrol., Skövde, Sweden (author)
  • Berlin, GöstaLinköpings universitet,Avdelningen för neuro- och inflammationsvetenskap,Medicinska fakulteten,Region Östergötland, Klinisk immunologi och transfusionsmedicin(Swepub:liu)gosbe95 (author)
  • Dykes, JosefinaLund University,Lunds universitet,Avdelningen för hematologi och transfusionsmedicin,Institutionen för laboratoriemedicin,Medicinska fakulteten,Division of Hematology and Transfusion Medicine,Department of Laboratory Medicine,Faculty of Medicine,Lund, Sweden(Swepub:lu)efor-jdy (author)
  • Toss, FBC, Umeå, Sweden (author)
  • Axelsson, C G (author)
  • Stegmayr, BerndUmeå universitet,Medicin(Swepub:umu)best0006 (author)
  • Nilsson, TNephrol, Uppsala, Sweden (author)
  • Norda, RBC, Uppsala, Sweden (author)
  • Knutson, FBC, Uppsala, Sweden (author)
  • Ramsauer, BerndSkövde(Swepub:umu)bera0016 (author)
  • Wahlström, A (author)
  • Umeå universitetMedicin (creator_code:org_t)

Related titles

  • In:Transfusion and apheresis science: Elsevier54:1, s. 2-151473-05021878-1683

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view