SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:umu-134"
 

Search: onr:"swepub:oai:DiVA.org:umu-134" > Heparin coating and...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Heparin coating and cardiotomy suction in cardiopulmonary bypass

Svenmarker, Staffan, 1951- (author)
Umeå universitet,Arkeologi och samiska studier
Åberg, Torkel (thesis advisor)
Engström, Gunnar (thesis advisor)
show more...
Karlsson, Thomas (thesis advisor)
Vaage, Jarle, Professor (opponent)
Department of Surgery Ullevål University Hospital, Oslo
show less...
 (creator_code:org_t)
ISBN 9173055239
2003
English 71 s.
Series: Umeå University medical dissertations, 0346-6612 ; 855
  • Doctoral thesis (other academic/artistic)
Abstract Subject headings
Close  
  • The present thesis addresses various means of reducing inflammatory responses associated with cardiopulmonary bypass (CPB) and retransfusion of pericardial suction blood (PSB) during cardiac surgery. Four (I-IV) prospective randomised controlled clinical trials comprising 475 patients were performed in the following areas: effects of heparin coating on measures of clinical outcome and memory function (I, II), inflammatory reactions in PSB and its systemic effects after retransfusion using cardiotomy suction or cell salvage (III) and effects of retransfusion of PSB on memory function and release patterns of protein S100B (IV). The use of heparin coated CPB-circuits was associated with a decrease of postoperative blood loss (I, II), transfusion requirements (II), shorter stay in hospital (I) decreased postoperative ventilator time (I), lower incidences of atrial fibrillation (II) and neurological deviations (I), reduction in releases of protein S100B (I, II) and lower postoperative creatinine elevation (I, II). PSB contained high concentrations of cytokines, complements, myeloperoxidase, free plasma haemoglobin and protein S100B (III, IV). Retransfusion using cardiotomy suction increased the systemic concentrations of free plasma haemoglobin and protein S100B, whereas retransfusion using cell salvage caused no detectable systemic effects (III, IV). CPB was associated with a small but significant release of protein S100B, despite elimination of PSB-contained protein S100B using cell salvage (IV). Subtle signs of impaired memory function were identified that were not associated with the use of heparin coated CPB-circuits (I, II) or retransfusion of PSB (IV). Key words: cardiopulmonary bypass, oxygenators, heparin, S100 proteins, blood loss, haemostasis, memory, outcome and process assessment.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Keyword

Surgery
cardiopulmonary bypass
oxygenators
heparin
S100 proteins
blood loss
haemostasis
memory
outcome and process assessment
Kirurgi
Surgery
Kirurgi
kirurgi
Surgery

Publication and Content Type

vet (subject category)
dok (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view