SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:umu-135128"
 

Search: onr:"swepub:oai:DiVA.org:umu-135128" > An adjustable CSF s...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

An adjustable CSF shunt : advices for clinical use

Lundkvist, B. (author)
Umeå universitet,Klinisk neurovetenskap
Eklund, Anders, 1965- (author)
Umeå universitet,Institutionen för strålningsvetenskaper
Koskinen, Lars-Owe D., Professor, 1955- (author)
Umeå universitet,Klinisk neurovetenskap
show more...
Malm, J. (author)
Umeå universitet,Klinisk neurovetenskap
show less...
 (creator_code:org_t)
2003-06-16
2003
English.
In: Acta Neurologica Scandinavica. - : Wiley-Blackwell. - 0001-6314 .- 1600-0404. ; 108:1, s. 38-42
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • OBJECTIVES: The opening pressure and the resistance of a CSF shunt are essential for clinical use in order to set the proper opening pressure and to determine the shunt function in vivo. We find it of vital importance to validate and supplement the product description given by the manufacturer. The in vitro properties of a newly introduced, adjustable differential pressure valve with a siphon-preventing device (Strata valve) was compared with its predecessor (Delta valve).METHODS: An automated, computerized experimental set-up based on regulation of pressure, built into an incubator at 37 degrees C, was used. Opening pressure, resistance and siphon preventing properties were determined. Six brand-new shunts of each type with catheters were tested. The Delta valves were at a performance level of 1.5.RESULTS: The hydrodynamic properties of the Strata and Delta valves were similar. The anti-siphoning device was functioning for all valves. The estimated mean resistance for Delta and Strata shunts was 2.6 +/- 0.4 and 2.2 +/- 1.0 mmHg/ml/min, respectively. The mean opening pressure for the five performance levels of the Strata shunt are: 3.3, 5.1, 7.7, 10.7 and 13.1 mmHg. There may however, be considerable variations between the shunts.CONCLUSIONS: The Strata shunt is a properly working adjustable valve with anti-siphoning device that showed good reproducibility concerning opening pressure and resistance. At performance level 1.5, the new Strata shunt was similar to its predecessor concerning opening pressure and resistance. The given values of the different opening pressures and resistance could be used for in vivo testing of the valve function with a standard lumbar CSF infusion test.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Neurologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Neurology (hsv//eng)

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Lundkvist, B.
Eklund, Anders, ...
Koskinen, Lars-O ...
Malm, J.
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Neurology
Articles in the publication
Acta Neurologica ...
By the university
Umeå University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view