SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:umu-14807"
 

Search: onr:"swepub:oai:DiVA.org:umu-14807" > A practical method ...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

A practical method to calculate head scatter factors in wedged rectangular and irregular MLC shaped beams for external and internal wedges

Georg, Dietmar (author)
Olofsson, Jörgen (author)
Umeå universitet,Radiofysik
Künzler, Thomas (author)
show more...
Aiginger, Hannes (author)
Karlsson, Mikael (author)
Umeå universitet,Radiofysik
show less...
 (creator_code:org_t)
2004-09-25
2004
English.
In: Physics in Medicine and Biology. - : IOP Publishing. - 0031-9155 .- 1361-6560. ; 49:20, s. 4689-4700
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Factor based methods for absorbed dose or monitor unit calculations are often based on separate data sets for open and wedged beams. The determination of basic beam parameters can be rather time consuming, unless equivalent square methods are applied. When considering irregular wedged beams shaped with a multileaf collimator, parametrization methods for dosimetric quantities, e.g. output ratios or wedge factors as a function of field size and shape, become even more important. A practical method is presented to derive wedged output ratios in air (S-c,S-w) for any rectangular field and for any irregular MLC shaped beam. This method was based on open field output ratios in air (Sc) for a field with the same collimator setting, and a relation f(w) between S-c,S-w and S-c. The relation f(w) can be determined from measured output ratios in air for a few open and wedged fields including the maximum wedged field size. The function fw and its parametrization were dependent on wedge angle and treatment head design, i.e. they were different for internal and external wedges. The proposed method was tested for rectangular wedged fields on three accelerators with internal wedges (GE, Elekta, BBC) and two accelerators with external wedges (Varian). For symmetric regular beams the average deviation between calculated and measured S-c,S-w/S-c ratios was 0.3% for external wedges and about 0.6% for internal wedges. Maximum deviations of 1.8% were obtained for elongated rectangular fields on the GE and ELEKTA linacs with an internal wedge. The same accuracy was achieved for irregular MLC shaped wedged beams on the accelerators with MLC and internal wedges (GE and Elekta), with an average deviation < 1 % for the fields tested. The proposed method to determine output ratios in air for wedged beams from output ratios of open beams, combined with equivalent square approaches, can be easily integrated in empirical or semi-empirical methods for monitor unit calculations. 

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Georg, Dietmar
Olofsson, Jörgen
Künzler, Thomas
Aiginger, Hannes
Karlsson, Mikael
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
Physics in Medic ...
By the university
Umeå University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view