Technical note : adapting a GE SIGNA PET/MR scanner for radiotherapy

Brynolfsson, Patrik (author)
Umeå universitet,Radiofysik
Axelsson, Jan, 1966- (author)
Umeå universitet,Radiofysik
Holmberg, August (author)
Umeå universitet,Radiofysik
show more...
Jonsson, Joakim, 1984- (author)
Umeå universitet,Radiofysik
Goldhaber, David (author)
Jian, Yiqiang (author)
Illerstam, Fredrik (author)
Engström, Mathias (author)
Zackrisson, Björn (author)
Umeå universitet,Onkologi
Nyholm, Tufve (author)
Umeå universitet,Radiofysik
show less...
 (creator_code:org_t)
2018-06-29
2018
English.
In: Medical physics (Lancaster). - : Wiley-Blackwell Publishing Inc.. - 0094-2405. ; 45:8, s. 3546-3550
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Purpose: Simultaneous collection of PET and MR data for radiotherapy purposes are useful for, for example, target definition and dose escalations. However, a prerequisite for using PET/MR in the radiotherapy workflow is the ability to image the patient in treatment position. The aim of this work was to adapt a GE SIGNA PET/MR scanner to image patients for radiotherapy treatment planning and evaluate the impact on signal-to-noise (SNR) of the MR images, and the accuracy of the PET attenuation correction. Method: A flat tabletop and a coil holder were developed to image patients in the treatment position, avoid patient contour deformation, and facilitate attenuation correction of flex coils. Attenuation corrections for the developed hardware and an anterior array flex coil were also measured and implemented to the PET/MR system to minimize PET quantitation errors. The reduction of SNR in the MR images due to the added distance between the coils and the patient was evaluated using a large homogenous saline-doped water phantom, and the activity quantitation errors in PET imaging were evaluated with and without the developed attenuation corrections. Result: We showed that the activity quantitation errors in PET imaging were within ±5% when correcting for attenuation of the flat tabletop, coil holder, and flex coil. The SNR of the MRI images were reduced to 74% using the tabletop, and 66% using the tabletop and coil holders. Conclusion: We present a tabletop and coil holder for an anterior array coil to be used with a GE SIGNA PET/MR scanner, for scanning patients in the radiotherapy work flow. Implementing attenuation correction of the added hardware from the radiotherapy setup leads to acceptable PET image quantitation. The drop in SNR in MR images may require adjustment of the imaging protocols.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

MRI
PET
PET
MR
quality assurance
radiotherapy

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view