Evaluation of urine dipsticks for quality control of residual erythrocytes and leukocytes in leukocyte-depleted donor plasma

Ekblom, Kim, 1970- (author)
Umeå universitet,Klinisk kemi,Department of Clinical Chemistry and Transfusion Medicine, Växjö Central Hospital, Växjö
Petersson, Annika (author)
 (creator_code:org_t)
2019-11-26
2020
English.
In: Scandinavian Journal of Clinical and Laboratory Investigation. - : Taylor & Francis. - 0036-5513 .- 1502-7686. ; 80:1, s. 39-45
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Currently used methodologies for quality control of residual leukocytes and erythrocytes in leukocyte-depleted plasma are either expensive or time-consuming. It has been proposed that urine dipsticks could be used as a screening method for residual erythrocytes. The aim was, therefore, to evaluate if urine dipsticks could be used to detect residual erythrocytes and also residual leukocytes in leukocyte-depleted plasma. Dilution series ranging over the decision limits for residual erythrocytes and leukocytes were prepared. Positive, negative and overall agreements, as well as the precision and joint frequency distributions, were calculated for five dipstick analyzers and their corresponding dipsticks. Twenty-four consecutive leukocyte-depleted donor plasma samples were also tested. None of the dipstick analyzers had both a high positive and a high negative agreement. Accordingly, none of the analyzers were able to discriminate between cell concentrations close to the decision limits. The inconsistency count revealed differences in precision between the dipstick analyzers. In the 24 consecutive donor samples, no significant correlation between the dipstick analyzers and the reference methods were found. In conclusion, urine dipsticks are not suitable for quality control of residual leukocytes and erythrocytes in leukocyte-depleted donor plasma.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Klinisk laboratoriemedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Clinical Laboratory Medicine (hsv//eng)

Keyword

Quality control
transfusion
red blood cell
point-of-care testing
plasma
practice guideline

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Ekblom, Kim, 197 ...
Petersson, Annik ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Clinical Laborat ...
Articles in the publication
Scandinavian Jou ...
By the university
Umeå University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view