SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:umu-174240"
 

Search: onr:"swepub:oai:DiVA.org:umu-174240" > Effects of Blood Ve...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Effects of Blood Vessels on Fat Channel Microwave Communication

Asan, Noor Badariah, 1984- (author)
Uppsala universitet,Fasta tillståndets elektronik,Univ Tekn Malaysia Melaka, Fac Elect & Comp Engn, Melaka, Malaysia.
Redzwan, Syaiful (author)
Uppsala universitet,Fasta tillståndets elektronik
Velander, Jacob (author)
Uppsala universitet,Fasta tillståndets elektronik
show more...
Perez, Mauricio D. (author)
Uppsala universitet,Fasta tillståndets elektronik
Augustine, Robin, 1982- (author)
Uppsala universitet,Fasta tillståndets elektronik
Voigt, Thiemo (author)
Uppsala universitet,Datorarkitektur och datorkommunikation
Hassan, Emadeldeen (author)
Umeå universitet,Institutionen för datavetenskap,Department of Electronics and Electrical Communications,Menoufia University, Menouf, Egypt,Umeå Univ, Dept Comp Sci, Umeå, Sweden.;Menoufia Univ, Dept Elect & Elect Commun, Menoufia, Egypt.
Blokhuis, Taco J. (author)
Maastricht Univ, Dept Surg, Med Ctr, Maastricht, Netherlands.
show less...
 (creator_code:org_t)
IEEE, 2018
2018
English.
In: 2018 IEEE Conference on Antenna Measurements & Applications (CAMA). - : IEEE. - 9781538657959
  • Conference paper (peer-reviewed)
Abstract Subject headings
Close  
  • This study aims to investigate the reliability of intra-body microwave propagation through the fat tissue in presence of blood vessels. Here, we consider three types of blood vessels with different sizes. We investigate the impact of the number of blood vessels and their alignment on the transmission of microwave signals through the fat channel. In our study, we employ two probes that act as a transmitter and a receiver. The probes are designed to operate at the Industrial, Scientific, and Medical radio band (2.45 GHz). For a channel length of 100 mm, our results indicate that the presence of the blood vessels may increase the channel path loss by similar to 1.5 dB and similar to 4.5 dB when the vessels are aligned and orthogonally aligned with the fat channel, respectively.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Kommunikationssystem (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Communication Systems (hsv//eng)

Keyword

microwave probes
dielectric properties
fat channel
blood vessels
intra-body communication
channel characterization

Publication and Content Type

ref (subject category)
kon (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view