Evaluation of a new cemented highly cross-linked all-polyethylene cup : a prospective and randomised study assessing wear and fixation characteristics using radiostereometric analysis

Otten, Volker, 1973- (author)
Umeå universitet,Ortopedi
Wästerlund, Daniel (author)
Umeå universitet,Ortopedi
Lindbjörn, John (author)
Umeå universitet,Ortopedi
show more...
Mertens, Carl (author)
Umeå universitet,Ortopedi
Mukka, Sebastian (author)
Umeå universitet,Ortopedi
Crnalic, Sead (author)
Umeå universitet,Ortopedi
Nilsson, Kjell G. (author)
Umeå universitet,Ortopedi
show less...
 (creator_code:org_t)
2021-02-10
2022
English.
In: HIP International. - : Sage Publications. - 1120-7000 .- 1724-6067. ; 32:6, s. 779-786
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • BACKGROUND AND PURPOSE: The aim of this prospective, randomised and controlled study was to evaluate the wear and fixation properties of a new cemented highly cross-linked all-polyethylene (HXLPE) cup in comparison with a conventional cemented ultra-high molecular weight polyethylene (ConvPE) cup using radiostereometric analysis (RSA).PATIENTS AND METHODS: A total of 58 patients (58 hips) with primary osteoarthritis (OA) were enrolled in a randomised controlled trial to receive either a ConvPE cup (control) or HXLPE cup (intervention) with identical geometry. The subjects were randomised in a 1:1 ratio. The primary endpoint was proximal wear measured as femoral head penetration into the cup, secondary outcomes were 3D-wear and annual proximal wear from 1 to 5 years. Cup fixation was measured as movement of the cup in relation to the acetabular bone with proximal migration being the primary outcome measure, 3D-migration and change in inclination as secondary outcomes. The patients were followed for 5 years with RSA performed postoperatively, at 3, 12, 24, and 60 months.RESULTS: The HXLPE displayed a lower median proximal femoral head penetration compared to ConvPE, with a median difference at 2 years of -0.07 mm (95% CI, -0.10 to -0.04 mm), and -0.19 mm (95% CI, -0.27 to -0.15 mm) at 5 years. Annual proximal wear between 1 and 5 years was 0.03 mm/year for HXLPE and 0.06 mm/year for ConvPE (mean difference 0.05 mm, [95% CI, 0.03-0.07 mm]). Proximal migration, 3D migration and change in inclination was numerically slightly higher for HXLPE, albeit not statistically significant.CONCLUSIONS: Compared to ConvPE, the HXLPE cup displayed significantly lower polyethylene wear. Cup migration was not statistically significant different.CLINICALTRIALS.GOV IDENTIFIER: NCT04322799.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)

Keyword

Highly cross-linked polyethylene
RCT
RSA
migration
wear

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view