  •    To hitlist

Comparison between a conventional treatment energy and 50 MV photons for the treatment of lung tumours

Blomquist, M (author)
Umeå universitet,Radiofysik
Li, J S (author)
Ma, C M (author)
show more...
Zackrisson, B (author)
Umeå universitet,Onkologi
Karlsson, Mikael (author)
Umeå universitet,Radiofysik
show less...
 (creator_code:org_t)
2002
2002
English.
In: Physics in Medicine and Biology. - 0031-9155 .- 1361-6560. ; 47:6, s. 889-897
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Radiation therapy in the thoracic region is difficult due to the presence of many dose-limiting structures and the large density differences that affect the dose distribution. Conventional irradiation techniques use low-energy photon beams to avoid build-up effects superficially in the tumour and increased lateral scattering of the beams. For deep-seated tumours higher beam energies could have lung-sparing properties that would enable dose escalation. A comparison was made for a conventional low photon energy (6 MV) and 50 MV photons for the treatment of a lung tumour. A representative patient geometry was selected, consisting of a small tumour semi-enclosed in lung tissue. Treatment plans were designed using a commercial 3D-pencil beam treatment planning system. The treatment beams designed in the TPS were simulated with the Monte Carlo code EGS4/BEAM and the dose distribution in the phantom created from the patients CT-data was calculated using MCDOSE with identical beam geometry for both energies. The intrinsic difference between the two photon energies implies a sparing effect of lung that can be utilized for dose escalation. For a treatment with two beams the mean total dose to the tumour could be increased by 5.3% for 50 MV, corresponding to 3.2 Gy for a prescription dose of 60 Gy, with the same complication probability for the treated lung as for 6 MV. In conclusion, high-energy beams have qualities that can be taken advantage of for irradiation of lung tumours. Optimum solutions would probably require the use of both high- and low-energy beams.

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Blomquist, M
Li, J S
Ma, C M
Zackrisson, B
Karlsson, Mikael
Articles in the publication
Physics in Medic ...
By the university
Umeå University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view