SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:umu-40046"
 

Search: onr:"swepub:oai:DiVA.org:umu-40046" > MR imaging of brain...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

MR imaging of brain volumes : evaluation of a fully automatic software

Ambarki, Khalid (author)
Umeå universitet,Radiofysik
Wåhlin, Anders (author)
Umeå universitet,Radiofysik
Birgander, Richard (author)
Umeå universitet,Diagnostisk radiologi
show more...
Eklund, Anders (author)
Umeå universitet,Radiofysik
Malm, Jan (author)
Umeå universitet,Klinisk neurovetenskap
show less...
 (creator_code:org_t)
2011
2011
English.
In: American Journal of Neuroradiology. - 0195-6108 .- 1936-959X. ; 32:2, s. 408-412
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • BACKGROUND AND PURPOSE: Automatic assessment of brain volumes is needed in researchand clinical practice. Manual tracing is still the criterionstandard but is time-consuming. It is important to validatethe automatic tools to avoid the problems of clinical studiesdrawing conclusions on the basis of brain volumes estimatedwith methodologic errors. The objective of this study was toevaluate a new commercially available fully automatic softwarefor MR imaging of brain volume assessment. Automatic and expertmanual brain volumes were compared. MATERIALS AND METHODS: MR imaging (3T, axial T2 and FLAIR) was performed in 41 healthyelderly volunteers (mean age, 70 ± 6 years) and 20 patientswith hydrocephalus (mean age, 73 ± 7 years). The softwareQBrain was used to manually and automatically measure the followingbrain volumes: ICV, BTV, VV, and WMHV. The manual method hasbeen previously validated and was used as the reference. Agreementbetween the manual and automatic methods was evaluated by usinglinear regression and Bland-Altman plots. RESULTS: There were significant differences between the automatic andmanual methods regarding all volumes. The mean differences wereICV = 49 ± 93 mL (mean ± 2SD, n = 61), BTV = 11± 70 mL, VV = –6 ± 10 mL, and WMHV = 2.4± 9 mL. The automatic calculations of brain volumes tookapproximately 2 minutes per investigation. CONCLUSIONS: The automatic tool is promising and provides rapid assessmentof brain volumes. However, the software needs improvement beforeit is incorporated into research or daily use. Manual segmentationremains the reference method.

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view