SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:umu-42801"
 

Search: onr:"swepub:oai:DiVA.org:umu-42801" > Internal fiducial m...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Internal fiducial markers and susceptibility effects in MRI : simulation and measurement of spatial accuracy

Jonsson, Joakim H (author)
Umeå universitet,Radiofysik
Garpebring, Anders (author)
Umeå universitet,Radiofysik
Karlsson, Magnus G (author)
Umeå universitet,Radiofysik
show more...
Nyholm, Tufve (author)
Umeå universitet,Radiofysik
show less...
 (creator_code:org_t)
Elsevier BV, 2012
2012
English.
In: International Journal of Radiation Oncology, Biology, Physics. - : Elsevier BV. - 0360-3016 .- 1879-355X. ; 82:5, s. 1612-1618
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • BACKGROUND: It is well-known that magnetic resonance imaging (MRI) is preferable to computed tomography (CT) in radiotherapy target delineation. To benefit from this, there are two options available: transferring the MRI delineated target volume to the planning CT or performing the treatment planning directly on the MRI study. A precondition for excluding the CT study is the possibility to define internal structures visible on both the planning MRI and on the images used to position the patient at treatment. In prostate cancer radiotherapy, internal gold markers are commonly used, and they are visible on CT, MRI, x-ray, and portal images. The depiction of the markers in MRI are, however, dependent on their shape and orientation relative the main magnetic field because of susceptibility effects. In the present work, these effects are investigated and quantified using both simulations and phantom measurements.METHODS AND MATERIALS: Software that simulated the magnetic field distortions around user defined geometries of variable susceptibilities was constructed. These magnetic field perturbation maps were then reconstructed to images that were evaluated. The simulation software was validated through phantom measurements of four commercially available gold markers of different shapes and one in-house gold marker.RESULTS: Both simulations and phantom measurements revealed small position deviations of the imaged marker positions relative the actual marker positions (<1 mm).CONCLUSION: Cylindrical gold markers can be used as internal fiducial markers in MRI.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

Fiducial markers
Gold
Magnetic resonance
Radiotherapy
Susceptibility

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Jonsson, Joakim ...
Garpebring, Ande ...
Karlsson, Magnus ...
Nyholm, Tufve
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
International Jo ...
By the university
Umeå University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view