An assessment of calibration and performance of the microdialysis system

Abrahamsson, Pernilla, 1972- (author)
Umeå universitet,Anestesiologi och intensivvård,Enheten för Anestesi och Intensivvård
Winsö, Ola (author)
Umeå universitet,Anestesiologi och intensivvård
 (creator_code:org_t)
Elsevier, 2005
2005
English.
In: Journal of Pharmaceutical and Biomedical Analysis. - : Elsevier. - 0731-7085 .- 1873-264X. ; 39:3-4, s. 730-734
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • To improve the reliability of microdialysis measurements of tissue concentrations of metabolic substances, this study was designed to test both the performance and the internal validity of the microdialysis methods in the hands of our research group. The stability of the CMA 600 analyser was tested with a known glucose solution in 72 standard microvials and in 48 plastic vials. To evaluate if variation in sampling time makes any difference in sample concentration (recovery), sampling times of 10, 20 and 30 min were compared in vitro with a constant flow rate of 1 microl/min. For testing of sampling times at different flow rates, an in vitro study was performed in which a constant sample volume of 10 microl was obtained. With the no net flux method, the actual concentration of glucose and urea in subcutaneous tissue was measured. The CMA 600 glucose analysis function was accurate and stable with a coefficient of variability (CV) of 0.2-0.55%. There was no difference in recovery for the CMA 60 catheter for glucose when sampling times were varied. Higher flow rates resulted in decreased recovery. Subcutaneous tissue concentrations of glucose and urea were 4.4 mmol/l and 4.1 mmol/l, respectively. To conclude, this work describes an internal validation of our use of the microdialysis system by calibration of vials and catheters. Internal validation is necessary in order to be certain of adequate sampling times, flow rates and sampling volumes. With this in mind, the microdialysis technique is useful and appropriate for in vivo studies on tissue metabolism.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Anestesi och intensivvård (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Anesthesiology and Intensive Care (hsv//eng)

Keyword

Calibration
Chemistry; Pharmaceutical/*methods
Drug Industry
Evaluation Studies as Topic
Glucose/analysis
Microdialysis/instrumentation/*methods
Quality Control
Reference Standards
Reproducibility of Results
Technology; Pharmaceutical/*methods
Time Factors
Urea/pharmacology
Anaesthetics and intensive care
Anestesiologi och intensivvård

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Abrahamsson, Per ...
Winsö, Ola
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Anesthesiology a ...
Articles in the publication
Journal of Pharm ...
By the university
Umeå University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view