SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:umu-82611"
 

Search: onr:"swepub:oai:DiVA.org:umu-82611" > Comprehensive profi...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Comprehensive profiling of 136 tetra- to octa-polychlorinated dibenzo-p-dioxins and dibenzofurans using ionic liquid columns and column combinations

Do, Lan (author)
Umeå universitet,Institutionen för medicinsk kemi och biofysik
Liljelind, Per (author)
Umeå universitet,Kemiska institutionen
Zhang, Jin (author)
Umeå universitet,Kemiska institutionen
show more...
Haglund, Peter (author)
Umeå universitet,Kemiska institutionen
show less...
 (creator_code:org_t)
Elsevier BV, 2013
2013
English.
In: Journal of Chromatography A. - : Elsevier BV. - 0021-9673 .- 1873-3778. ; 1311, s. 157-169
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The orders of elution of all 136 tetra- to octa-chlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were determined on six gas chromatography (GC) columns. Three of these columns had ionic liquid stationary phases (SLB-IL111, SLB-IL76 and SLB-IL61; Supelco), one a liquid crystal phase (LC-50; Restek), one a chiral phase (beta DEXcst; Restek) and one a low bleed non-polar phase (DB-XLB; J&W/Agilent). According to our results, the high polarity and multiple solvation interactions of the ionic liquid stationary phases offered superior resolving power to that achieved with previously evaluated columns. The SLB-IL61 and SLB-IL111 columns resolved or partially separated 106 and 100 congeners, respectively, of the 136 PCDD/Fs. The SLB-IL61 also resolved 15 and partially separated one of the seventeen 2,3,7,8-substituted PCDD/Fs. Additional congeners can be separated by complementary analyses using additional columns in a dual- or triple-column approach. For example, using a combination of the SLB-IL61 and SLB-IL111 columns all but 8 congeners would be separated, including all 2,3,7,8-substituted PCDD/Fs. Two more congeners would be separated using a combination of SLB-IL76 and a liquid crystal (SB-Smectic) column, but in this case the 2,3,7,8-TeCDF would not be resolved. Three-column combinations would give even better separation: the DB-17/Smectic/SLB-IL76 and DB-225/Smectic/SLB-IL111 combinations would separate all but 1 of the 136 PCDD/F congeners. Unfortunately, the smectic column is no longer in production. If only commercially available columns are considered, combinations of SLB-IL61 and SLB-IL111 with DB-XLB, LC-50, or DB-225 offer the best performance, with 4, 4, and 3 unresolved congeners, respectively. Moreover, in each of these cases, one of the congeners in each unresolved pair is resolved on at least one of the other columns and so a reasonable estimate of the unresolved congeners' concentrations can be obtained by subtraction. The profiling of all 136 PCDD/Fs is thus greatly facilitated by using ionic liquid columns or combinations including such columns. However, there is room for improvement in the technical performance of the evaluated ionic liquid columns: their long-term retention time stability was poor and some highly chlorinated and sterically hindered congeners underwent dehalogenation during separation.(C) 2013 Elsevier B.V. All rights reserved.

Subject headings

NATURVETENSKAP  -- Kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences (hsv//eng)
NATURVETENSKAP  -- Biologi -- Biokemi och molekylärbiologi (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences -- Biochemistry and Molecular Biology (hsv//eng)

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Do, Lan
Liljelind, Per
Zhang, Jin
Haglund, Peter
About the subject
NATURAL SCIENCES
NATURAL SCIENCES
and Chemical Science ...
NATURAL SCIENCES
NATURAL SCIENCES
and Biological Scien ...
and Biochemistry and ...
Articles in the publication
Journal of Chrom ...
By the university
Umeå University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view