SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:umu-84150"
 

Search: onr:"swepub:oai:DiVA.org:umu-84150" > The influence of ti...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

The influence of time sampling scheme on kinetic parameters obtained from compartmental modeling of a dynamic PET study : a Monte Carlo study

Häggström, Ida (author)
Umeå universitet,Radiofysik
Larsson, Anne (author)
Umeå universitet,Radiofysik
Axelsson, Jan (author)
Umeå universitet,Radiofysik
show more...
Garpebring, Anders (author)
Umeå universitet,Radiofysik
Johansson, Lennart (author)
Umeå universitet,Radiofysik
Schmidtlein, C. Ross (author)
Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, USA
Sörensen, Jens (author)
Medical Sciences, Nuclear Medicine, Uppsala University Hospital, Uppsala, Sweden
Karlsson, Mikael (author)
Umeå universitet,Radiofysik
show less...
 (creator_code:org_t)
Anaheim : IEEE conference proceedings, 2012
2012
English.
In: IEEE Nuclear Science Symposium Conference Record. - Anaheim : IEEE conference proceedings. - 9781467320306 ; , s. 3101-3107
  • Conference paper (peer-reviewed)
Abstract Subject headings
Close  
  • Compartmental modeling of dynamic PET data enables quantification of tracer kinetics in vivo, through the obtained model parameters. The dynamic data is sorted into frames during or after the acquisition, with a sampling interval usually ranging from 10 s to 300 s. In this study we wanted to investigate the effect of the chosen sampling interval on kinetic parameters obtained from a 2-tissue model, in terms of bias and standard deviation, using a complete Monte Carlo simulated dynamic F-18-FLT PET study. The results show that the bias and standard deviation in parameter K-1 is small regardless of sampling scheme or noise in the time-activity curves (TACs), and that the bias and standard deviation in k(4) is large for all cases. The bias in V-a is clearly dependent on sampling scheme, increasing for increased sampling interval. In general, a too short sampling interval results in very noisy images and a large bias of the parameter estimate, and a too long sampling interval also increases bias. Noise in the TACs is the largest source of bias.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Keyword

PET
dynamic PET
Monte Carlo
GATE
compartment model
time sampling
sampling interval
AIF
FLT
radiofysik
radiation physics

Publication and Content Type

ref (subject category)
kon (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view