SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:uu-103598"
 

Search: onr:"swepub:oai:DiVA.org:uu-103598" > Relations of serum ...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Hansson, JonasUppsala universitet,Institutionen för medicinska vetenskaper (author)

Relations of serum MMP-9 and TIMP-1 levels to left ventricular measures and cardiovascular risk factors : a population-based study

  • Article/chapterEnglish2009

Publisher, publication year, extent ...

  • 2009
  • printrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:uu-103598
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-103598URI
  • https://doi.org/10.1097/HJR.0b013e3283213108DOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • BACKGROUND: Extracellular matrix remodeling is a hallmark of pathological left ventricular (LV) hypertrophy and heart failure. This process is tightly controlled by the degrading matrix metalloproteinases (MMPs) and their tissue inhibitors (TIMPs). We hypothesized that circulating MMP-9 and TIMP-1 levels are altered already in persons with the signs of LV remodeling that forego clinical heart failure. DESIGN: Cross-sectional study in the Prospective Investigation of the Vasculature in Uppsala Seniors , a community-based cohort of 891 70-year-old men and women free from valvular disease, heart failure, and myocardial infarction. METHODS: We examined relations of serum MMP-9 and TIMP-1 to echocardiographic LV geometry and function. All models were adjusted for sex, height, intra-arterial systolic and diastolic blood pressures, antihypertensive medication use, and serum freezer time. RESULTS: Serum TIMP-1 was positively related to LV mass and wall thickness (r=0.15, P<0.0001 and r=0.16, P<0.0001, respectively), with a 32 g higher LV mass and 2.2 mm thicker walls in the fourth compared with the first quartile of serum TIMP-1. Serum TIMP-1 was also inversely related to LV ejection fraction (r=-0.10, P=0.009), but not to LV dimension or diastolic function indices. Serum MMP-9 was only weakly related to LV wall thickness and isovolumic relaxation time (r=0.08, P=0.04 and r=-0.08, P=0.04). CONCLUSION: In this large population-based sample, serum TIMP-1 levels were related to LV mass, wall thickness, and inversely to systolic function. This may imply that extracellular matrix remodeling is involved already in the earliest stages of the process leading to heart failure.

Subject headings and genre

  • MEDICINE
  • MEDICIN

Added entries (persons, corporate bodies, meetings, titles ...)

  • Lind, LarsUppsala universitet,Institutionen för medicinska vetenskaper(Swepub:uu)laeli995 (author)
  • Hulthe, Johannes (author)
  • Sundström, JohanUppsala universitet,Institutionen för medicinska vetenskaper(Swepub:uu)johasund (author)
  • Uppsala universitetInstitutionen för medicinska vetenskaper (creator_code:org_t)

Related titles

  • In:European Journal of Cardiovascular Prevention & Rehabilitation16:3, s. 297-3031741-82671741-8275

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view