Search: onr:"swepub:oai:DiVA.org:uu-152127" >
Milrinone Increases...
-
Arbeus, MikaelDept of Cardiothoracic Surgery and Anesthesiology, Örebro University hospital
(author)
Milrinone Increases Flow in Coronary Artery Bypass Grafts After Cardiopulmonary Bypass : A Prospective, Randomized, Double-Blind, Placebo-Controlled Study
- Article/chapterEnglish2009
Publisher, publication year, extent ...
-
Elsevier BV,2009
-
printrdacarrier
Numbers
-
LIBRIS-ID:oai:DiVA.org:uu-152127
-
https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-152127URI
-
https://doi.org/10.1053/j.jvca.2008.07.005DOI
-
https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-68817URI
Supplementary language notes
-
Language:English
-
Summary in:English
Part of subdatabase
Classification
-
Subject category:ref swepub-contenttype
-
Subject category:art swepub-publicationtype
Notes
-
Objective: To compare the effects of a bolus of milrinone, 50 mu g/kg, versus placebo on flow in coronary artery bypass grafts after cardiopulmonary bypass (CPB). Design: A prospective, randomized, double-blind study. Setting: A university hospital. Participants: Forty-four patients with stable angina and left ventricular ejection fraction > 30% scheduled for elective coronary artery bypass graft (CABG) surgery were included. Intervention: Patients were randomized to receive 50 mu g/kg of milrinone (n = 22) or placebo (n = 22) after aortic declamping. Measurements and Main Results: The flow in coronary artery bypass grafts was measured with a transit time flow meter at 10 minutes and 30 minutes after termination of CPB. The hemodynamic evaluation included transesophageal echocardiography, mean arterial pressure (MAP), heart rate, and intracavitary measurement of left ventricular end-diastolic pressure (LVEDP). The flow in the saphenous vein grafts was significantly higher in the milrinone group when compared with the placebo group both at 10 and 30 minutes after termination of CPB (p < 0.001). At 10 minutes, the flow was 64.5 +/- 37.4 mL/min (mean +/- standard deviation) and 43.6 +/- 25.7 mL/min in nonsequential vein grafts for milrinone and placebo, respectively. Corresponding values at 30 minutes were 54.8 +/- 29.9 mL/min and 35.3 +/- 22.4 mL/min. The left internal thoracic artery (LITA) flow was higher in the milrinone group but did not reach statistical significance. The fractional area change was higher, and the MAP and calculated pressure gradient (MAP-LVEDP) were lower at 10 minutes in the milrinone group. Conclusion: Milrinone significantly increases the flow in anastomosed saphenous vein grafts after CPB, and has beneficial effects on left ventricular function.
Subject headings and genre
Added entries (persons, corporate bodies, meetings, titles ...)
-
Axelsson, BirgerDept of Cardiothoracic Surgery and Anesthesiology, Örebro University hospital
(author)
-
Friberg, OrjanDept of Cardiothoracic Surgery and Anesthesiology, Örebro University hospital
(author)
-
Magnuson, AndersStatistical and Epidemiological Unit, Örebro University hospital
(author)
-
Bodin, LennartStatistical and Epidemiological Unit, Örebro University hospital
(author)
-
Hultman, JanUppsala universitet,Anestesiologi och intensivvård,Dept of Thoracic and Cardiovascular Anesthesio, Uppsala University hospital
(author)
-
Dept of Cardiothoracic Surgery and Anesthesiology, Örebro University hospitalStatistical and Epidemiological Unit, Örebro University hospital
(creator_code:org_t)
Related titles
-
In:Journal of Cardiothoracic and Vascular Anesthesia: Elsevier BV23:1, s. 48-531053-07701532-8422
Internet link
Find in a library
To the university's database