SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:uu-171224"
 

Search: onr:"swepub:oai:DiVA.org:uu-171224" > Glioma grading by u...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Glioma grading by using histogram analysis of blood volume heterogeneity from MR-derived cerebral blood volume maps.

Emblem, Kyrre E (author)
Nedregaard, Baard (author)
Nome, Terje (author)
show more...
Due-Tonnessen, Paulina (author)
Hald, John K (author)
Scheie, David (author)
Casar-Borota, Olivera (author)
Umeå universitet,Patologi,Olivera Casar-Borotas publikationer
Cvancarova, Milada (author)
Bjornerud, Atle (author)
show less...
 (creator_code:org_t)
Radiological Society of North America (RSNA), 2008
2008
English.
In: Radiology. - : Radiological Society of North America (RSNA). - 0033-8419 .- 1527-1315. ; 247:3, s. 808-17
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • PURPOSE: To retrospectively compare the diagnostic accuracy of an alternative method used to grade gliomas that is based on histogram analysis of normalized cerebral blood volume (CBV) values from the entire tumor volume (obtained with the histogram method) with that of the hot-spot method, with histologic analysis as the reference standard.MATERIALS AND METHODS: The medical ethics committee approved this study, and all patients provided informed consent. Fifty-three patients (24 female, 29 male; mean age, 48 years; age range, 14-76 years) with histologically confirmed gliomas were examined with dynamic contrast material-enhanced 1.5-T magnetic resonance (MR) imaging. CBV maps were created and normalized to unaffected white matter (normalized CBV maps). Four neuroradiologists independently measured the distribution of whole-tumor normalized CBVs and analyzed this distribution by classifying the values into area-normalized bins. Glioma grading was performed by assessing the normalized peak height of the histogram distributions. Logistic regression analysis and interobserver agreement were used to compare the proposed method with a hot-spot method in which only the maximum normalized CBV was used.RESULTS: For the histogram method, diagnostic accuracy was independent of the observer. Interobserver agreement was almost perfect for the histogram method (kappa = 0.923) and moderate for the hot-spot method (kappa = 0.559). For all observers, sensitivity was higher with the histogram method (90%) than with the hot-spot method (55%-76%).CONCLUSION: Glioma grading based on histogram analysis of normalized CBV heterogeneity is an alternative to the established hot-spot method, as it offers increased diagnostic accuracy and interobserver agreement.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Klinisk laboratoriemedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Clinical Laboratory Medicine (hsv//eng)

Keyword

Pathology
Patologi

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

  • Radiology (Search for host publication in LIBRIS)

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view