SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:uu-17216"
 

Search: onr:"swepub:oai:DiVA.org:uu-17216" > Symptoms, complaint...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Symptoms, complaints, ocular and nasal physiological signs in university staff in relation to indoor environment : temperature and gender interactions

Bakke, J V (author)
Norbäck, D (author)
Uppsala universitet,Arbets- och miljömedicin,Eva Vingård
Wieslander, G (author)
Uppsala universitet,Arbets- och miljömedicin,Eva Vingård
show more...
Hollund, B-E (author)
Florvaag, E (author)
Haugen, E N (author)
Moen, B E (author)
show less...
 (creator_code:org_t)
Hindawi Limited, 2008
2008
English.
In: Indoor Air. - : Hindawi Limited. - 0905-6947 .- 1600-0668. ; 18:2, s. 131-143
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Symptoms, signs, perceptions, and objective measures were studied in university buildings. Two problem buildings with a history of dampness and complaints were compared with two control buildings. Health investigations among university staff were performed at the workplace (n = 173) including tear film stability [non-invasive break-up time (NIBUT) and self-reported break-up time (SBUT)], nasal patency (acoustic rhinometry), nasal lavage fluid analysis [NAL: eosinophil cationic protein (ECP), myeloperoxidase (MPO), lysozyme and albumin] and atopy by total serum IgE and IgE antibodies (Phadiatop (R)). Exposure assessment included inspections, thermal and atmospheric climate at 56 points modelled for all work sites. Multiple regressions were applied, controlling for age and gender. Exposure differences between problem buildings and controls were small, and variations between rooms were greater. Workers in the problem buildings had more general and dermal symptoms, but not more objective signs than the others. Adjusted day NIBUT and SBUT increased at higher night air temperatures, with B (95% CI) 0.6 (0.04-1.2) and 1.3 (-0.02 to 2.5), respectively. Higher relative humidity at mean day air temperature < 22.1 degrees C was associated with adjusted NIBUT and SBUT, with B (95% CI) 0.16 (0.03-0.29) and 0.37 (-0.01 to 0.75), respectively. Air velocity below recommended winter values and reduced relative humidity in the range of 15-30% were associated with dry air and too low temperature.

Keyword

indoor air quality
thermal climate
thermal comfort
tear film
nasal patency
building-related perceptions
MEDICINE
MEDICIN

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

  • Indoor Air (Search for host publication in LIBRIS)

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view