SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:uu-182298"
 

Search: onr:"swepub:oai:DiVA.org:uu-182298" > Intravoxel Incohere...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Intravoxel Incoherent Motion MR Imaging of the Kidney : Pilot Study

Eckerbom, Per, 1974- (author)
Uppsala universitet,Enheten för radiologi,Uppsala universitet, Enheten för radiologi
Hansell, Peter (author)
Uppsala universitet,Integrativ Fysiologi,Uppsala universitet, Integrativ Fysiologi
Bjerner, Tomas (author)
Uppsala universitet,Enheten för radiologi,Uppsala universitet, Enheten för radiologi
show more...
Palm, Fredrik (author)
Uppsala universitet,Integrativ Fysiologi,Uppsala universitet, Integrativ Fysiologi
Weis, Jan (author)
Uppsala universitet,Enheten för radiologi,Uppsala universitet, Enheten för radiologi
Liss, Per (author)
Uppsala universitet,Enheten för radiologi,Uppsala universitet, Enheten för radiologi
show less...
 (creator_code:org_t)
2012-07-21
2013
English.
In: Advances in Experimental Medicine and Biology. - New York, NY : Springer New York. - 0065-2598 .- 2214-8019. ; 765, s. 55-58
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • MR examinations (Achieva 3 T, Philips, Best, The Netherlands) were performed at five different occasions in a healthy volunteer (male 60 years) and in one renal cancer patient (male 78 years) with normal renal function (creatinine 88 μmol/L). Intravoxel incoherent motion (IVIM) coefficients D + D* were measured using respiratory-triggered diffusion-weighted spin-echo echo-planar imaging. Perfusion data of the patient were acquired using a saturation-recovery gradient-echo sequence and with the bolus of Gd-BOPTA (Multihance). D + D* were computed by monoexponential fitting of MR signal intensity attenuation versus b for b = 0, 50, 100, 150 s/mm2. Perfusion parameters were evaluated with “NordicICE” software. The map of D + D* was compared qualitatively with the perfusion map computed from the Gd scan. D + D* values of the cortex and medulla were in the range 2.3–2.7 and 1.1–1.6 × 10-3 mm2/s, respectively. In conclusion, in this pilot study a good qualitative relation between IVIM variables D + D* and renal perfusion has been found.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view