Measurement of urinary cystatin C with a particle-enhanced turbidimetric immunoassay on architect ci8200

Noraddin, Feria Hikmet (author)
Uppsala universitet,Biokemisk struktur och funktion,Klinisk kemi
Flodin, Mats (author)
Uppsala universitet,Biokemisk struktur och funktion,Klinisk kemi
Fredricsson, Annika (author)
Uppsala universitet,Biokemisk struktur och funktion,Klinisk kemi
show more...
Sohrabian, Azita (author)
Uppsala universitet,Biokemisk struktur och funktion,Klinisk kemi
Larsson, Anders (author)
Uppsala universitet,Biokemisk struktur och funktion,Klinisk kemi
show less...
 (creator_code:org_t)
2012-09-21
2012
English.
In: Journal of clinical laboratory analysis (Print). - : Wiley. - 0887-8013 .- 1098-2825. ; 26:5, s. 358-364
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • BACKGROUND:Cystatin C is a low-molecular-weight protein that is freely filtered by the glomerulus and catabolized after reabsorption by the proximal tubular cells in healthy subjects. Urinary cystatin C is a potential biomarker for tubular damage including acute kidney injury (AKI) in the acute phase when patients are submitted to the intensive care unit.METHODS:The aim of this study was to perform a method validation of urinary analysis of cystatin C by particle-enhanced turbidimetric immunoassay (PETIA) on a high-throughput chemical analyzer. Total assay time was 10 min. The antigen excess, linearity, lower limit of quantification (LoQ), recovery, assay precision, stability, and interference caused by hemoglobin were evaluated.RESULTS:The LoQ was calculated to 0.020 mg/l with a coefficient of variation (CV) ≤ 10%. No hook effect was observed and the assay was linear over the studied interval less than 0.020-0.950 mg/l with a regression of R(2) = 0.9994. The assay had a recovery between 93-100% and the assay precision had a total CV of less than 3.5%. Cystatin C was stable for 3 days in room temperature and 14 days in +4C. The assay did not show any major interference with hemoglobin at a hemoglobin concentration of 10 g/L. The reference interval for urine cystatin C was less than 0.166 mg/l.CONCLUSION:The urinary cystatin C PETIA showed good precision and performance characteristics including short test turnaround times that are necessary qualifications for a biomarker at a routine laboratory.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Urologi och njurmedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Urology and Nephrology (hsv//eng)

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Noraddin, Feria ...
Flodin, Mats
Fredricsson, Ann ...
Sohrabian, Azita
Larsson, Anders
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Urology and Neph ...
Articles in the publication
Journal of clini ...
By the university
Uppsala University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view