SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:uu-220132"
 

Search: onr:"swepub:oai:DiVA.org:uu-220132" > Reliability of comp...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Reliability of computed tomography measurements in assessment of thigh muscle cross-sectional area and attenuation

Strandberg, Sören (author)
Karolinska Institutet
Wretling, Marie-Louise (author)
Karolinska Institutet
Wredmark, Torsten (author)
show more...
Shalabi, Adel (author)
Uppsala universitet,Enheten för radiologi,Department of Radiology, Karolinska University Hospital, Karolinska Institutet, Stockholm, Sweden
show less...
 (creator_code:org_t)
2010-08-11
2010
English.
In: BMC Medical Imaging. - : Springer Science and Business Media LLC. - 1471-2342. ; 10, s. 18-
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • BACKGROUND: Advancement in technology of computer tomography (CT) and introduction of new medical imaging softwares enables easy and rapid assessment of muscle cross-sectional area (CSA) and attenuation. Before using these techniques in clinical studies there is a need for evaluation of the reliability of the measurements. The purpose of the study was to evaluate the inter- and intra-observer reliability of ImageJ in measuring thigh muscles CSA and attenuation in patients with anterior cruciate ligament (ACL) injury by computer tomography.METHODS: 31 patients from an ongoing study of rehabilitation and muscle atrophy after ACL reconstruction were included in the study. Axial CT images with slice thickness of 10 mm at the level of 150 mm above the knee joint were analyzed by two investigators independently at two times with a minimum of 3 weeks between the two readings using NIH ImageJ. CSA and the mean attenuation of individual thigh muscles were analyzed for both legs.RESULTS: Mean CSA and mean attenuation values were in good agreement both when comparing the two observers and the two replicates. The inter- and intraclass correlation (ICC) was generally very high with values from 0.98 to 1.00 for all comparisons except for the area of semimembranosus. All the ICC values were significant (p < 0,001). Pearson correlation coefficients were also generally very high with values from 0.98 to 1.00 for all comparisons except for the area of semimembranosus (0.95 for intraobserver and 0.92 for interobserver).CONCLUSION: This study has presented ImageJ as a method to monitor and evaluate CSA and attenuation of different muscles in the thigh using CT-imaging. The method shows an overall excellent reliability with respect to both observer and replicate.

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view