SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:uu-239233"
 

Search: onr:"swepub:oai:DiVA.org:uu-239233" > Fluorescence imagin...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Chu, JiangtaoUppsala universitet,Mikrosystemteknik (author)

Fluorescence imaging of macromolecule transport in high molecular weight cut-off microdialysis

  • Article/chapterEnglish2014

Publisher, publication year, extent ...

  • 2014-10-07
  • Springer Science and Business Media LLC,2014
  • printrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:uu-239233
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-239233URI
  • https://doi.org/10.1007/s00216-014-8192-yDOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • When microdialysis (MD) membrane exceeds molecular weight cut-off (MWCO) of 100 kDa, the fluid mechanics are in the ultrafiltration regime. Consequently, fluidic mass transport of macromolecules in the perfusate over the membrane may reduce the biological relevance of the sampling and cause an inflammatory response in the test subject. Therefore, a method to investigate the molecular transport of high MWCO MD is presented. An in vitro test chamber was fabricated to facilitate the fluorescent imaging of the MD sampling process, using fluoresceinylisothiocyanate (FITC) dextran and fluorescence microscopy. Qualitative studies on dextran behavior inside and outside the membrane were performed. Semiquantitative results showed clear dextran leakage from both 40 and 250 kDa dextran when 100 kDa MWCO membranes were used. Dextran 40 kDa leaked out with an order of magnitude higher concentration and the leakage pattern resembled more of a convective flow pattern compared with dextran 250 kDa, where the leakage pattern was more diffusion based. No leakage was observed when dextran 500 kDa was used as a colloid osmotic agent. The results in this study suggest that fluorescence imaging could be used as a method for qualitative and semiquantitative molecular transport and fluid dynamics studies of MD membranes and other hollow fiber catheter membranes.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Koudriavtsev, VitaliUppsala universitet,Mikrosystemteknik (author)
  • Hjort, KlasUppsala universitet,Mikrosystemteknik(Swepub:uu)klashjor (author)
  • Dahlin, Andreas P,1976-Uppsala universitet,Mikrosystemteknik(Swepub:uu)anpet516 (author)
  • Uppsala universitetMikrosystemteknik (creator_code:org_t)

Related titles

  • In:Analytical and Bioanalytical Chemistry: Springer Science and Business Media LLC406:29, s. 7601-76091618-26421618-2650

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Chu, Jiangtao
Koudriavtsev, Vi ...
Hjort, Klas
Dahlin, Andreas ...
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Medical Engineer ...
and Other Medical En ...
Articles in the publication
Analytical and B ...
By the university
Uppsala University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view