SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-251858"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-251858" > Recirculation durin...

  • Broman, MikaelKarolinska Institutet,Uppsala universitet,Institutionen för medicinsk cellbiologi,ECMO Department, Karolinska University Hospital, Stockholm (författare)

Recirculation during veno-venous extra-corporeal membrane oxygenation - a simulation study

  • Artikel/kapitelEngelska2015

Förlag, utgivningsår, omfång ...

  • 2014-12-27
  • SAGE Publications,2015
  • electronicrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:uu-251858
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-251858URI
  • https://doi.org/10.5301/ijao.5000373DOI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-159647URI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:hj:diva-37067URI
  • http://kipublications.ki.se/Default.aspx?queryparsed=id:130916711URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • QC 20150213
  • Purpose: Veno-venous ECMO is indicated in reversible life-threatening respiratory failure without life-threatening circulatory failure. Recirculation of oxygenated blood in the ECMO circuit decreases efficiency of patient oxygen delivery but is difficult to measure. We seek to identify and quantify some of the factors responsible for recirculation in a simulation model and compare with clinical data. Methods: A closed-loop real-time simulation model of the cardiovascular system has been developed. ECMO is simulated with a fixed flow pump 0 to 5 l/min with various cannulation sites -1) right atrium to inferior vena cava, 2) inferior vena cava to right atrium, and 3) superior+ inferior vena cava to right atrium. Simulations are compared to data from a retrospective cohort of 11 consecutive adult veno-venous ECMO patients in our department. Results: Recirculation increases with increasing ECMO-flow, decreases with increasing cardiac output, and is highly dependent on choice of cannulation sites. A more peripheral drainage site decreases recirculation substantially. Conclusions: Simulations suggest that recirculation is a significant clinical problem in veno-venous ECMO in agreement with clinical data. Due to the difficulties in measuring recirculation and interpretation of the venous oxygen saturation in the ECMO drainage blood, flow settings and cannula positioning should rather be optimized with help of arterial oxygenation parameters. Simulation may be useful in quantification and understanding of recirculation in VV-ECMO.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Frenckner, BjornKarolinska Institutet (författare)
  • Bjällmark, AnnaKTH,Medicinsk bildteknik,KTH, Medicinsk bildteknik(Swepub:hj)bjaann (författare)
  • Broomé, MichaelKarolinska Institutet,KTH,Medicinsk bildteknik,KTH, Medicinsk bildteknik(Swepub:kth)u1boiixx (författare)
  • Uppsala universitetInstitutionen för medicinsk cellbiologi (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:International Journal of Artificial Organs: SAGE Publications38:1, s. 23-300391-39881724-6040

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy