  • Mansor, Syahir (author)

Parametric Methods for Dynamic (11)C-Phenytoin PET Studies.

  • Article/chapterEnglish2017

Publisher, publication year, extent ...

  • 2016-09-22
  • Society of Nuclear Medicine,2017
  • printrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:uu-317725
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-317725URI
  • https://doi.org/10.2967/jnumed.116.178707DOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • In this study, the performance of various methods for generating quantitative parametric images of dynamic (11)C-phenytoin PET studies was evaluated. Methods: Double-baseline 60-min dynamic (11)C-phenytoin PET studies, including online arterial sampling, were acquired for 6 healthy subjects. Parametric images were generated using Logan plot analysis, a basis function method, and spectral analysis. Parametric distribution volume (VT) and influx rate (K1) were compared with those obtained from nonlinear regression analysis of time-activity curves. In addition, global and regional test-retest (TRT) variability was determined for parametric K1 and VT values. Results: Biases in VT observed with all parametric methods were less than 5%. For K1, spectral analysis showed a negative bias of 16%. The mean TRT variabilities of VT and K1 were less than 10% for all methods. Shortening the scan duration to 45 min provided similar VT and K1 with comparable TRT performance compared with 60-min data. Conclusion: Among the various parametric methods tested, the basis function method provided parametric VT and K1 values with the least bias compared with nonlinear regression data and showed TRT variabilities lower than 5%, also for smaller volume-of-interest sizes (i.e., higher noise levels) and shorter scan duration.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Yaqub, Maqsood (author)
  • Boellaard, Ronald (author)
  • Froklage, Femke E (author)
  • de Vries, Anke (author)
  • Bakker, Esther D M (author)
  • Voskuyl, Rob A (author)
  • Eriksson, JonasUppsala universitet,Avdelningen för Molekylär Avbildning(Swepub:uu)joeri542 (author)
  • Schwarte, Lothar A (author)
  • Verbeek, Joost (author)
  • Windhorst, Albert D (author)
  • Lammertsma, Adriaan A (author)
  • Uppsala universitetAvdelningen för Molekylär Avbildning (creator_code:org_t)

Related titles

  • In:Journal of Nuclear Medicine: Society of Nuclear Medicine58:3, s. 479-4830161-55051535-56672159-662X

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view