SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:uu-317727"
 

Search: onr:"swepub:oai:DiVA.org:uu-317727" > Parametric Binding ...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Parametric Binding Images of the TSPO Ligand 18F-DPA-714.

Golla, Sandeep S V (author)
Boellaard, Ronald (author)
Oikonen, Vesa (author)
show more...
Hoffmann, Anja (author)
van Berckel, Bart N M (author)
Windhorst, Albert D (author)
Virta, Jere (author)
Te Beek, Erik T (author)
Groeneveld, Geert Jan (author)
Haaparanta-Solin, Merja (author)
Luoto, Pauliina (author)
Savisto, Nina (author)
Solin, Olof (author)
Valencia, Ray (author)
Thiele, Andrea (author)
Eriksson, Jonas (author)
Uppsala universitet,Avdelningen för Molekylär Avbildning
Schuit, Robert C (author)
Lammertsma, Adriaan A (author)
Rinne, Juha O (author)
show less...
 (creator_code:org_t)
2016-06-03
2016
English.
In: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 57:10, s. 1543-1547
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • (18)F-labeled N,N-diethyl-2-(2-[4-(2-fluoroethoxy)phenyl]-5,7-dimethylpyrazolo[1,5-α]pyrimidine-3-yl)acetamide (DPA-714) is a radioligand for the 18-kDa translocator protein. The purpose of the present study was to identify the best method for generating quantitative parametric images of (18)F-DPA-714 binding.METHODS: Ninety-minute dynamic (18)F-DPA-714 PET scans with full arterial sampling from 6 healthy subjects and 9 Alzheimer disease (AD) patients were used. Plasma-input-based Logan graphical analysis and spectral analysis were used to generate parametric volume of distribution (VT) images. Five versions of Ichise, reference Logan, and 2 basis function implementations (receptor parametric mapping and simplified reference tissue model 2 [SRTM2]) of SRTM, all using gray matter cerebellum as the reference region, were applied to generate nondisplaceable binding potential (BPND) images.RESULTS: Plasma-input Logan analysis (r(2) = 0.99; slope, 0.88) and spectral analysis (r(2) = 0.99, slope, 0.93) generated estimates of VT that correlated well with values obtained using nonlinear regression. BPND values generated using SRTM2 (r(2) = 0.83; slope, 0.95) and reference Logan analysis (r(2) = 0.88; slope, 1.01) correlated well with nonlinear regression-based estimates.CONCLUSION: Both Logan analysis and spectral analysis can be used to obtain quantitatively accurate VT images of (18)F-DPA-714. In addition, SRTM2 and reference Logan analysis can provide accurate BPND images. These parametric images could be used for voxel-based comparisons.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

18F-DPA-714
PET
TSPO
parametric images

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view