Search: onr:"swepub:oai:DiVA.org:uu-335970" >
Simplifying Logisti...
Simplifying Logistics and Avoiding the Unnecessary in Patients with Breast Cancer Undergoing Sentinel Node Biopsy. A Prospective Feasibility Trial of the Preoperative Injection of Super Paramagnetic Iron Oxide Nanoparticles
-
- Karakatsanis, Andreas (author)
- Uppsala universitet,Endokrinkirurgi
-
- Olofsson, Helena (author)
- Uppsala universitet,Klinisk och experimentell patologi
-
- Stålberg, Peter (author)
- Uppsala universitet,Endokrinkirurgi
-
show more...
-
- Bergkvist, Leif (author)
- Uppsala universitet,Centrum för klinisk forskning, Västerås
-
- Abdsaleh, S (author)
- Uppsala universitet,Radiologi
-
- Wärnberg, Fredrik (author)
- Uppsala universitet,Endokrinkirurgi,Gastrointestinal Surgery
-
show less...
-
(creator_code:org_t)
- 2017-11-13
- 2018
- English.
-
In: Scandinavian Journal of Surgery. - : SAGE Publications. - 1457-4969 .- 1799-7267. ; 107:2, s. 130-137
- Related links:
-
https://journals.sag...
-
show more...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- PURPOSE: Sentinel node is routinely localized with the intraoperative use of a radioactive tracer, involving challenging logistics. Super paramagnetic iron oxide nanoparticle is a non-radioactive tracer with comparable performance that could allow for preoperative localization, would simplify the procedure, and possibly be of value in axillary mapping before neoadjuvant treatment. The current trial aimed to determine the a priori hypothesis that the injection of super paramagnetic iron oxide nanoparticles in the preoperative period for the localization of the sentinel node is feasible.METHODS: This is a prospective feasibility trial, conducted from 9 September 2014 to 22 October 2014 at Uppsala University Hospital. In all, 12 consecutive patients with primary breast cancer planned for resection of the primary and sentinel node biopsy were recruited. Super paramagnetic iron oxide nanoparticles were injected in the preoperative visit in the outpatient clinic. The radioactive tracer (99mTc) and the blue dye were injected perioperatively in standard fashion. A volunteer was injected with super paramagnetic iron oxide nanoparticles to follow the decline in the magnetic signal in the sentinel node over time. The primary outcome was successful sentinel node detection.RESULTS: Super paramagnetic iron oxide nanoparticles' detection after preoperative injection (3-15 days) was successful in all cases (100%). In the volunteer, axillary signal was presented for 4 weeks. No adverse effects were noted. Conclusion and relevance: Preoperative super paramagnetic iron oxide nanoparticles' injection is feasible and leads to successful detection of the sentinel node. That may lead to simplified logistics as well as the identification, sampling, and marking of the sentinel node in patients planned for neoadjuvant treatment.
Subject headings
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Klinisk laboratoriemedicin (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Clinical Laboratory Medicine (hsv//eng)
Keyword
- Super paramagnetic iron oxide
- breast cancer
- novel technique
- sentinel node biopsy
- Surgery
- Kirurgi
- Patologi
- Pathology
Publication and Content Type
- ref (subject category)
- art (subject category)
Find in a library
To the university's database