Search: onr:"swepub:oai:DiVA.org:uu-353002" >
Do dual-mobility cu...
-
Brüggemann, AndersUppsala universitet,Ortopedi
(author)
Do dual-mobility cups cemented into porous tantalum shells reduce the risk of dislocation after revision surgery? : A retrospective cohort study on 184 patients
- Article/chapterEnglish2018
Publisher, publication year, extent ...
-
2018-02-05
-
TAYLOR & FRANCIS LTD,2018
-
electronicrdacarrier
Numbers
-
LIBRIS-ID:oai:DiVA.org:uu-353002
-
https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-353002URI
-
https://doi.org/10.1080/17453674.2018.1432927DOI
Supplementary language notes
-
Language:English
-
Summary in:English
Part of subdatabase
Classification
-
Subject category:ref swepub-contenttype
-
Subject category:art swepub-publicationtype
Notes
-
Background and purpose Dual-mobility cups (DMCs) reduce the risk of dislocation and porous tantalum (TM) shells show favorable osseointegration after acetabular revision surgery, yet the combination of these implants has not been studied. We hypothesized that (1) cementing a DMC into a TM shell decreases the risk of dislocation; (2) DMCs cemented into TM shells are not at greater risk of re-revision; (3) liberation of tantalum ions is marginal after use of this combined technique.Patients and methods We investigated the outcome in 184 hips (184 patients) after acetabular revision surgery with TM shells, fitted either with DMCs (n = 69), or with standard polyethylene (PE) liners (n = 115). Chart follow-up was complete for all patients, and the occurrence of dislocations and re-revisions was recorded. 20 were deceased, 50 were unable to attend follow-up, leaving 114 for assessment of hip function after 4.9 (0.5-8.9) years, radiographs were obtained in 99, and tantalum concentrations in 84 patients.Results 1 patient with a DMC had a dislocation, whereas 14 patients with PE liners experienced at least 1 dislocation. 11 of 15 re-revisions in the PE group were necessitated by dislocations, whereas none of the 2 re-revisions in the DMC group was performed for this reason. Hence, dislocation-free survival after 4 years was 99% (95% CI 96-100) in the DMC group, whereas it was 88% (CI 82-94, p = 0.01) in the PE group. We found no radiographic signs of implant failure in any patient. Mean tantalum concentrations were 0.1 mu l/L (CI 0.05-0.2) in the DMC group and 0.1 mu g/L (CI 0.05-0.2) in the PE group.Interpretation Cementing DMCs into TM shells reduces the risk of dislocation after acetabular revision surgery without jeopardizing overall cup survival, and without enhancing tantalum release.
Subject headings and genre
Added entries (persons, corporate bodies, meetings, titles ...)
-
Mallmin, HansUppsala universitet,Ortopedi(Swepub:uu)hansmall
(author)
-
Hailer, Nils PUppsala universitet,Ortopedi(Swepub:uu)nilha837
(author)
-
Uppsala universitetOrtopedi
(creator_code:org_t)
Related titles
-
In:Acta Orthopaedica: TAYLOR & FRANCIS LTD89:2, s. 156-1621745-36741745-3682
Internet link
Find in a library
To the university's database