SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:uu-368888"
 

Search: onr:"swepub:oai:DiVA.org:uu-368888" > Test-retest reliabi...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Baron, TomaszUppsala universitet,Uppsala kliniska forskningscentrum (UCR),Kardiologi,Klinisk fysiologi (author)

Test-retest reliability of new and conventional echocardiographic parameters of left ventricular systolic function

  • Article/chapterEnglish2019

Publisher, publication year, extent ...

  • 2018-10-27
  • Springer Science and Business Media LLC,2019
  • electronicrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:uu-368888
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-368888URI
  • https://doi.org/10.1007/s00392-018-1363-7DOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • Background: Reliability of left ventricular function measurements depends on actual biological conditions, repeated registrations and their analyses.Objective: To investigate test–retest reliability of speckle-tracking-derived strain measurements and its determinants compared to the conventional parameters, such as ejection fraction (EF), LV volumes and mitral annular plane systolic excursion (MAPSE).Methods: In 30 patients with a wide range of left ventricular function (mean EF 46.4 ± 16.4%, range 14–73%), standard echo views were acquired independently in a blinded fashion by two different echocardiographers in immediate sequence and analyzed off-line by two independent readers, creating 4 data sets per patient. Test–retest reliability of studied parameters was calculated using the smallest detectable change (SDC) and a total, inter-acquisition and inter-reader intra-class correlation coefficient (ICC).Results: The smallest detectable change normalized to the mean absolute value of the measured parameter (SDCrel) was lowest for MAPSE (10.7%). SDCrel for EF was similar to GLS (14.2 and 14.7%, respectively), while SDCrel for CS was much higher (35.6%). The intra-class correlation coefficient was excellent (> 0.9) for all measures of the left ventricular function. Intra-patient inter-acquisition reliability (ICCacq) was significantly better than inter-reader reliability (ICCread) (0.984 vs. 0.950, p = 0.03) only for EF, while no significant difference was observed for any other LV function parameter. Mean intra-subject standard deviations were significantly correlated to the mean values for CS and LV volumes, but not for the other studied parameters.Conclusions: In a test–retest setting, both with normal and impaired left ventricular function, the smallest relative detectable change of EF, GLS and MAPSE was similar (11–15%), but was much higher for CS (35%). Surprisingly, reliability of GLS was not superior to that of EF. Acquisition and reader to a similar extent influenced the reliability of measurements of all left ventricular function measures except for ejection fraction, where the reliability was more dependent on the reader than on the acquisition.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Berglund, Lars,1955-Uppsala universitet,Uppsala kliniska forskningscentrum (UCR),Geriatrik(Swepub:uu)larsbelu (author)
  • Hedin, Eva-MariaUppsala universitet,Kardiologi-arrytmi(Swepub:uu)evamhedi (author)
  • Flachskampf, Frank,1957-Uppsala universitet,Klinisk fysiologi,Kardiologi(Swepub:uu)frafl698 (author)
  • Uppsala universitetUppsala kliniska forskningscentrum (UCR) (creator_code:org_t)

Related titles

  • In:Clinical Research in Cardiology: Springer Science and Business Media LLC108:4, s. 355-3651861-06841861-0692

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Baron, Tomasz
Berglund, Lars, ...
Hedin, Eva-Maria
Flachskampf, Fra ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Cardiac and Card ...
Articles in the publication
Clinical Researc ...
By the university
Uppsala University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view