SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:uu-368999"
 

Search: onr:"swepub:oai:DiVA.org:uu-368999" > Fault signatures an...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Samuelsson, OscarUppsala universitet,Avdelningen för systemteknik,Reglerteknik,IVL Swedish Environm Res Inst, Stockholm, Sweden,Uppsala University, Sweden,Division of Systems and Control, Department of Information Technology (author)

Fault signatures and bias progression in dissolved oxygen sensors

  • Article/chapterEnglish2018

Publisher, publication year, extent ...

  • 2018-08-22
  • IWA Publishing,2018
  • electronicrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:uu-368999
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-368999URI
  • https://doi.org/10.2166/wst.2018.350DOI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:mdh:diva-40533URI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • Biofilm fouling is known to impact the data quality of sensors, but little is known about the exact effects. We studied the effects of artificial and real biofilm fouling on dissolved oxygen (DO) sensors in full-scale water resource recovery facilities, and how this can automatically be detected. Biofilm fouling resulted in different drift direction and bias magnitudes for optical (OPT) and electrochemical (MEC) DO sensors. The OPT-sensor was more affected by biofilm fouling compared to the MEC-sensor, especially during summer conditions. A bias of 1 mg/L was detected by analysing the impulse response (IR) of the automatic air cleaning system in the DO sensor. The IR is an effect of a temporal increase in DO concentration during the automatic air cleaning. The IRs received distinct pattern changes that were matched with faults including: biofilm fouling, disturbances in the air supply to the cleaning system, and damaged sensor membrane, which can be used for fault diagnosis. The results highlight the importance of a condition-based sensor maintenance schedule in contrast to fixed cleaning intervals. Further, the results stress the importance of understanding and detecting bias due to biofilm fouling, in order to maintain a robust and resource-efficient process control.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Bjork, AndersIVL Swedish Environm Res Inst, Stockholm, Sweden,IVL Swedish Environmental Research Institute, Sweden. (author)
  • Zambrano, JesusMälardalens högskola,Framtidens energi(Swepub:mdh)jzo01 (author)
  • Carlsson, BengtUppsala universitet,Reglerteknik,Avdelningen för systemteknik,Uppsala Univ, Uppsala, Sweden,Uppsala University, Sweden,Division of Systems and Control, Department of Information Technology(Swepub:uu)bengtcar (author)
  • Uppsala universitetAvdelningen för systemteknik (creator_code:org_t)

Related titles

  • In:Water Science and Technology: IWA Publishing78:5, s. 1034-10440273-12231996-9732

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Samuelsson, Osca ...
Bjork, Anders
Zambrano, Jesus
Carlsson, Bengt
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Electrical Engin ...
and Other Electrical ...
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Environmental En ...
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Environmental Bi ...
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Civil Engineerin ...
and Water Engineerin ...
Articles in the publication
Water Science an ...
By the university
Uppsala University
Mälardalen University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view