Evaluation of Automated Determination of Bilirubin and Oxyhemoglobin in Cerebrospinal Fluid Using the DrugLog© Instrument

Larsson, Anders (author)
Uppsala universitet,Klinisk kemi
Lipcsey, Miklós (author)
Uppsala universitet,Hedenstiernalaboratoriet,Anestesiologi och intensivvård
Dahlin, Hans (author)
Pharmacolog AB, Uppsala, Sweden
show more...
Andersson, Magdalena (author)
Uppsala universitet,Hedenstiernalaboratoriet
show less...
 (creator_code:org_t)
Clinical Laboratory Publications, 2020
2020
English.
In: Clinical Laboratory. - : Clinical Laboratory Publications. - 1433-6510. ; 66:11, s. 2357-2364
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • BACKGROUND: In a heterogenous group of patients with acute headache it is important to diagnose subarachnoid hemorrhage (SAH), a potentially lethal but treatable condition, with short turnaround time and high precision. Spectrophotometry of cerebrospinal fluid (CSF) is an essential part in the investigation of patients with suspected SAH but the analysis is slow and operator dependent.METHODS: We have evaluated a new instrument for ultraviolet and visible light (UV-VIS) spectroscopy (DrugLog©, Pharmacolog, Uppsala, Sweden) for automatic determination of oxyhemoglobin and bilirubin in CSF samples. The instrument incorporates software for calculating the absorbance values thus eliminating operator bias. Bilirubin and oxyhemoglobin in CSF was analyzed both with DrugLog© and traditional spectrophotometry at 415 and 476 nanometers (A415 and A476) using patient samples containing varying amounts of bilirubin and oxyhemoglobin.RESULTS: The DrugLog© method showed a strong correlation both for bilirubin (Pearson's r = 0.996) and oxyhemo-globin (Pearson's r = 0.993). The DrugLog© method had good linearity and precision, offering an automated determination of bilirubin and oxyhemoglobin, eliminating operator bias.CONCLUSIONS: The DrugLog© instrument has a short assay time and showed good agreement with traditional spectrophotometry.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Klinisk laboratoriemedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Clinical Laboratory Medicine (hsv//eng)

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Larsson, Anders
Lipcsey, Miklós
Dahlin, Hans
Andersson, Magda ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Clinical Laborat ...
Articles in the publication
Clinical Laborat ...
By the university
Uppsala University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view