Harmonisation of PET/CT contrast recovery performance for brain studies
-
Verwer, E E (author)
-
Golla, S S V (author)
-
Kaalep, A (author)
-
show more...
-
- Lubberink, Mark (author)
- Uppsala universitet,Radiologi
-
van Velden, F H P (author)
-
Bettinardi, V (author)
-
Yaqub, M (author)
-
Sera, T (author)
-
Rijnsdorp, S (author)
-
Lammertsma, A A (author)
-
Boellaard, R (author)
-
show less...
-
(creator_code:org_t)
- 2021-01-31
- 2021
- English.
-
In: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer. - 1619-7070 .- 1619-7089. ; 48:9, s. 2856-2870
- Related links:
-
https://doi.org/10.1...
-
show more...
-
https://uu.diva-port... (primary) (Raw object)
-
https://link.springe...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- PURPOSE: In order to achieve comparability of image quality, harmonisation of PET system performance is imperative. In this study, prototype harmonisation criteria for PET brain studies were developed.METHODS: Twelve clinical PET/CT systems (4 GE, 4 Philips, 4 Siemens, including SiPM-based "digital" systems) were used to acquire 30-min PET scans of a Hoffman 3D Brain phantom filled with ~ 33 kBq·mL-1 [18F]FDG. Scan data were reconstructed using various reconstruction settings. The images were rigidly coregistered to a template (voxel size 1.17 × 1.17 × 2.00 mm3) onto which several volumes of interest (VOIs) were defined. Recovery coefficients (RC) and grey matter to white matter ratios (GMWMr) were derived for eroded (denoted in the text by subscript e) and non-eroded grey (GM) and white (WM) matter VOIs as well as a mid-phantom cold spot (VOIcold) and VOIs from the Hammers atlas. In addition, left-right hemisphere differences and voxel-by-voxel differences compared to a reference image were assessed.RESULTS: Systematic differences were observed for reconstructions with and without point-spread-function modelling (PSFON and PSFOFF, respectively). Normalising to image-derived activity, upper and lower limits ensuring image comparability were as follows: for PSFON, RCGMe = [0.97-1.01] and GMWMre = [3.51-3.91] for eroded VOI and RCGM = [0.78-0.83] and GMWMr = [1.77-2.06] for non-eroded VOI, and for PSFOFF, RCGMe = [0.92-0.99] and GMWMre = [3.14-3.68] for eroded VOI and RCGM = [0.75-0.81] and GMWMr = [1.72-1.95] for non-eroded VOI.CONCLUSIONS: To achieve inter-scanner comparability, we propose selecting reconstruction settings based on RCGMe and GMWMre as specified in "Results". These proposed standards should be tested prospectively to validate and/or refine the harmonisation criteria.
Subject headings
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Keyword
- Brain
- Harmonisation
- Image quality
- Neuroimaging
- PET
- Standardisation
Publication and Content Type
- ref (subject category)
- art (subject category)
Find in a library
To the university's database
- By the author/editor
-
Verwer, E E
-
Golla, S S V
-
Kaalep, A
-
Lubberink, Mark
-
van Velden, F H ...
-
Bettinardi, V
-
show more...
-
Yaqub, M
-
Sera, T
-
Rijnsdorp, S
-
Lammertsma, A A
-
Boellaard, R
-
show less...
- About the subject
-
- MEDICAL AND HEALTH SCIENCES
-
MEDICAL AND HEAL ...
-
and Clinical Medicin ...
-
and Radiology Nuclea ...
- Articles in the publication
-
European Journal ...
- By the university
-
Uppsala University