SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:uu-464092"
 

Search: onr:"swepub:oai:DiVA.org:uu-464092" > Performance of a No...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Performance of a Novel Research-Use-Only Secretoneurin ELISA in Patients with Suspected Acute Coronary Syndrome : Comparison with an Established Secretoneurin Radioimmunoassay

Myhre, Peder L (author)
Institute of Clinical Medicine, University of Oslo, Oslo, Norway
Ottesen, Anett H (author)
Institute for Experimental Medical Research, Oslo University Hospital, Ullevål, Oslo, Norway
Faaren, Arne L (author)
show more...
Tveit, Sjur H (author)
Institute of Clinical Medicine, University of Oslo, Oslo, Norway
Springett, Jon (author)
Pyylampi, Johanna (author)
Stridsberg, Mats (author)
Uppsala universitet,Klinisk kemi,Biokemisk endokrinologi
Christensen, Geir (author)
Institute of Clinical Medicine, University of Oslo, Oslo, Norway
Høiseth, Arne Didrik (author)
Omland, Torbjørn (author)
Røsjø, Helge (author)
Institute of Clinical Medicine, University of Oslo, Oslo, Norway
show less...
 (creator_code:org_t)
2021-07-20
2021
English.
In: Cardiology. - : S. Karger. - 0008-6312 .- 1421-9751. ; 146:5, s. 566-574
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Background: Circulating secretoneurin (SN) concentrations, as measured by established radioimmunoassay (RIA), risk stratify patients with cardiovascular disease. We now report data for a recently developed research-use-only SN enzyme-linked immunosorbent assay (ELISA) in patients with suspected acute coronary syndrome (ACS).Methods: SN ELISA was developed according to industry standards and tested in 401 unselected chest pain patients. Blood samples were drawn <24 h from admission, and we adjudicated all hospitalizations as ACS or non-ACS. The mean follow-up was 6.2 years.Results: SN ELISA with 2 monoclonal sheep anti-SN antibodies has a measuring range of 10–250 pmol/L and demonstrates excellent analytical precision and accuracy across the range of SN concentrations. SN measured by ELISA and RIA correlated in the chest pain patients: rho = 0.39, p < 0.001. SN concentrations were higher in ACS patients (n = 161 [40%]) than in non-ACS patients (n = 240) for both assays, with an area under the curve (AUC) of 0.66 (95% CI: 0.61–0.71) for ELISA and 0.59 (0.54–0.65) for RIA. SN concentrations were also higher in nonsurvivors (n = 65 [16%]) than survivors, with an AUC of 0.72 (0.65–0.79) for ELISA versus 0.64 (0.56–0.72) for RIA, p = 0.007, for difference between assays. Adjusting for age, sex, blood pressure, previous myocardial infarction, atrial fibrillation, and heart failure in multivariable analysis, SN concentrations as measured by ELISA, but not RIA, remained associated with mortality, with a hazard ratio of 1.71 (1.03–2.84), p = 0.038.Conclusions: The novel SN ELISA has excellent performance, higher AUC for diagnosis, and superior prognostic accuracy compared to the established RIA in chest pain patients. 

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Keyword

Secretoneurin
Enzyme-linked immunosorbent assay
Acute coronary syndrome

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

  • Cardiology (Search for host publication in LIBRIS)

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view