SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:uu-487295"
 

Search: onr:"swepub:oai:DiVA.org:uu-487295" > Suction cup on a pi...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Mälberg, JohanUppsala universitet,Anestesiologi och intensivvård,Uppsala Univ Hosp, Emergency Med Serv EMS, Sjukhusvagen, S-75185 Uppsala, Sweden. (author)

Suction cup on a piston-based chest compression device improves coronary perfusion pressure and cerebral oxygenation during experimental cardiopulmonary resuscitation

  • Article/chapterEnglish2022

Publisher, publication year, extent ...

  • Elsevier,2022
  • electronicrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:uu-487295
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-487295URI
  • https://doi.org/10.1016/j.resplu.2022.100311DOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • Introduction: The presented study aimed to investigate whether a mechanical chest compression piston device with a suction cup assisting chest recoil could impact the hemodynamic status when compared to a bare piston during cardiopulmonary resuscitation.Methods: 16 piglets were anesthetized and randomized into 2 groups. After 3 minutes of induced ventricular fibrillation, a LUCAS 3 device was used to perform chest compressions, in one group a suction cup was mounted on the device's piston, while in the other group, compressions were per -formed by the bare piston. The device was used in 30:2 mode and the animals were manually ventilated. Endpoints of the study were: end tidal carbon dioxide, coronary and cerebral perfusion pressures, and brain oxygenation (measured using near infrared spectroscopy). At the end of the protocol, the animals that got a return to spontaneous circulation were observed for 60 minutes, then euthanized.Results: No difference was found in end tidal carbon dioxide or tidal volumes. Coronary perfusion pressure and cerebral oxygenation were higher in the Suction cup group over the entire experiment time, while cerebral perfusion pressure was higher only in the last 5 minutes of CPR. A passive tidal volume (air going in and out the airways during compressions) was detected and found correlated to end tidal carbon dioxide.Conclusions: The use of a suction cup on a piston-based chest compression device did not increase end tidal carbon dioxide, but it was associated to a higher coronary perfusion pressure.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Smekal, David,1971-Uppsala universitet,Anestesiologi och intensivvård,Uppsala Univ Hosp, Emergency Med Serv EMS, Sjukhusvagen, S-75185 Uppsala, Sweden.(Swepub:uu)davsm531 (author)
  • Marchesi, SilviaJolife Stryker AB, S-23633 Scheelevagen, Sweden. (author)
  • Lipcsey, MiklósUppsala universitet,Hedenstiernalaboratoriet(Swepub:uu)milip123 (author)
  • Rubertsson, StenUppsala universitet,Anestesiologi och intensivvård(Swepub:uu)stenrube (author)
  • Uppsala universitetAnestesiologi och intensivvård (creator_code:org_t)

Related titles

  • In:Resuscitation Plus: Elsevier122666-5204

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view