Transmission-Based Vertebrae Strength Probe Development : Far Field Probe Property Extraction and Integrated Machine Vision Distance Validation Experiments

Meaney, Paul (author)
Uppsala universitet,Institutionen för elektroteknik,Dartmouth Coll, Thayer Sch Engn, Hanover, NH 03755 USA.
Augustine, Robin, 1982- (author)
Uppsala universitet,Fasta tillståndets elektronik
Welteke, Adrian (author)
Helmut Schmidt Univ, Elect Engn Dept, D-22043 Hamburg, Germany.
show more...
Pfrommer, Bernd (author)
Pearson, Adam M. (author)
Dartmouth Coll, Geisel Sch Med, Lebanon, NH 03766 USA.
Brisby, Helena (author)
Sahlgrenska Hosp, Orthoped Dept, S-41345 Gothenburg, Sweden.
show less...
 (creator_code:org_t)
MDPI AG, 2023
2023
English.
In: Sensors. - : MDPI AG. - 1424-8220. ; 23:10
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • We are developing a transmission-based probe for point-of-care assessment of vertebrae strength needed for fabricating the instrumentation used in supporting the spinal column during spinal fusion surgery. The device is based on a transmission probe whereby thin coaxial probes are inserted into the small canals through the pedicles and into the vertebrae, and a broad band signal is transmitted from one probe to the other across the bone tissue. Simultaneously, a machine vision scheme has been developed to measure the separation distance between the probe tips while they are inserted into the vertebrae. The latter technique includes a small camera mounted to the handle of one probe and associated fiducials printed on the other. Machine vision techniques make it possible to track the location of the fiducial-based probe tip and compare it to the fixed coordinate location of the camera-based probe tip. The combination of the two methods allows for straightforward calculation of tissue characteristics by exploiting the antenna far field approximation. Validation tests of the two concepts are presented as a precursor to clinical prototype development.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Keyword

vertebrae
instrumentation
osteoporosis
microwave
transmission
machine vision
surgical navigation

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

  • Sensors (Search for host publication in LIBRIS)

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Meaney, Paul
Augustine, Robin ...
Welteke, Adrian
Pfrommer, Bernd
Pearson, Adam M.
Brisby, Helena
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Electrical Engin ...
Articles in the publication
Sensors
By the university
Uppsala University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view