Simulations and experiments on a 12 kW direct driven PM synchronous generator for wind power

Eriksson, Sandra (author)
Uppsala universitet,Elektricitetslära
Solum, Andreas (author)
Uppsala universitet,Elektricitetslära
Leijon, Mats (author)
Uppsala universitet,Elektricitetslära
show more...
Bernhoff, Hans (author)
Uppsala universitet,Elektricitetslära
show less...
 (creator_code:org_t)
Elsevier BV, 2008
2008
English.
In: Renewable energy. - : Elsevier BV. - 0960-1481 .- 1879-0682. ; 33:4, s. 674-681
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • A direct driven permanent magnet (PM) synchronous generator has been designed and constructed and results from the first experimental tests are presented. The generator has been designed using the finite element method (FEM) and dynamic simulations have been performed to study the generator. The simulations are performed by using an electromagnetic model, which is described by a combined field and circuit equation model and is solved in a finite element environment. The stator winding of the generator consists of circular cables and the rotor has surface mounted, arched PMs. A complete experimental setup has been constructed consisting of a motor, a frequency converter, a gearbox and electrical loads. Oscilloscopes are used to measure the voltage and the current for each phase. Measurements have been performed for both full load and no load at rated speed. The harmonic content of the voltage is analyzed and compared to results from simulations. Furthermore, the generated electric power has been calculated from knowing the voltage and current and is compared to the simulated power. The agreement between experimental results and results from simulations based on finite element calculations is very high.. especially considering harmonics. Several sources of error are suggested that could cause the small differences between the simulated results and the measured data for the constructed generator.

Keyword

synchronous generator
wind power
experiments
simulations
harmonics
TECHNOLOGY
TEKNIKVETENSKAP

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Eriksson, Sandra
Solum, Andreas
Leijon, Mats
Bernhoff, Hans
Articles in the publication
Renewable energy
By the university
Uppsala University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view