Search: onr:"swepub:oai:gup.ub.gu.se/117581" >
ViewDEX: an efficie...
-
Håkansson, MarkusGothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
(author)
ViewDEX: an efficient and easy-to-use software for observer performance studies
- Article/chapterEnglish2010
Publisher, publication year, extent ...
-
2010-03-03
-
Oxford University Press (OUP),2010
Numbers
-
LIBRIS-ID:oai:gup.ub.gu.se/117581
-
https://gup.ub.gu.se/publication/117581URI
-
https://doi.org/10.1093/rpd/ncq057DOI
Supplementary language notes
Part of subdatabase
Classification
-
Subject category:ref swepub-contenttype
-
Subject category:art swepub-publicationtype
Notes
-
The development of investigation techniques, image processing, workstation monitors, analysing tools etc. within the field of radiology is vast, and the need for efficient tools in the evaluation and optimisation process of image and investigation quality is important. ViewDEX (Viewer for Digital Evaluation of X-ray images) is an image viewer and task manager suitable for research and optimisation tasks in medical imaging. ViewDEX is DICOM compatible and the features of the interface (tasks, image handling and functionality) are general and flexible. The configuration of a study and output (for example, answers given) can be edited in any text editor. ViewDEX is developed in Java and can run from any disc area connected to a computer. It is free to use for non-commercial purposes and can be downloaded from http://www.vgregion.se/sas/viewdex. In the present work, an evaluation of the efficiency of ViewDEX for receiver operating characteristic (ROC) studies, free-response ROC (FROC) studies and visual grading (VG) studies was conducted. For VG studies, the total scoring rate was dependent on the number of criteria per case. A scoring rate of approximately 150 cases h(-1) can be expected for a typical VG study using single images and five anatomical criteria. For ROC and FROC studies using clinical images, the scoring rate was approximately 100 cases h(-1) using single images and approximately 25 cases h(-1) using image stacks ( approximately 50 images case(-1)). In conclusion, ViewDEX is an efficient and easy-to-use software for observer performance studies.
Subject headings and genre
Added entries (persons, corporate bodies, meetings, titles ...)
-
Svensson, Sune
(author)
-
Zachrisson, SaraGothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics(Swepub:gu)xzacsa
(author)
-
Svalkvist, AngelicaGothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics(Swepub:gu)xsvala
(author)
-
Båth, Magnus,1974Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics(Swepub:gu)xbatma
(author)
-
Månsson, Lars Gunnar,1951Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics(Swepub:gu)xmanla
(author)
-
Göteborgs universitetInstitutionen för kliniska vetenskaper
(creator_code:org_t)
Related titles
-
In:Radiation protection dosimetry: Oxford University Press (OUP)139:1-3, s. 42-511742-34060144-8420
Internet link
Find in a library
To the university's database