  • Sund, PatrikGothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics (author)

Investigation of the effect of ambient lighting on contrast sensitivity using a novel method for conducting visual research on LCDs

  • Article/chapterEnglish2010

Publisher, publication year, extent ...

  • 2010-03-08
  • Oxford University Press (OUP),2010

Numbers

  • LIBRIS-ID:oai:gup.ub.gu.se/119326
  • https://gup.ub.gu.se/publication/119326URI
  • https://doi.org/10.1093/rpd/ncq067DOI

Supplementary language notes

  • Language:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • The DICOM part 14 greyscale standard display function provides one way of harmonising image appearance under different monitor luminance settings. This function is based on ideal observer conditions, where the eye is always adapted to the target luminance and thereby also at peak contrast sensitivity. Clinical workstations are, however, often submitted to variations in ambient light due to a sub-optimal reading room light environment. Also, clinical images are inhomogeneous and low-contrast patterns must be detected even at luminance levels that differ from the eye adaptation level. All deviations from ideal luminance conditions cause the observer to detect patterns with reduced eye sensitivity but the magnitude of this reduction is unclear. A method is presented to display well-defined sinusoidal low-contrast test patterns on an liquid crystal display. The observers were exposed to light from three different areas: (i) the test pattern covering approximately 2 degrees x 2 degrees ; (ii) the remaining of the display surface and (iii) ambient light from outside the display area covering most of the observers' field of view. By adjusting the luminance from each of these three areas, the observers' ability to detect low-contrast patterns under sub-optimal viewing conditions was studied. Ambient light from outside the display area has a moderate effect on the contrast threshold, except for the combination of high ambient light and dark objects, where the contrast threshold increased considerably.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Båth, Magnus,1974Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics(Swepub:gu)xbatma (author)
  • Månsson, Lars Gunnar,1951Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics(Swepub:gu)xmanla (author)
  • Göteborgs universitetInstitutionen för kliniska vetenskaper, Avdelningen för radiofysik (creator_code:org_t)

Related titles

  • In:Radiation protection dosimetry: Oxford University Press (OUP)139:1-3, s. 62-701742-34060144-8420

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Sund, Patrik
Båth, Magnus, 19 ...
Månsson, Lars Gu ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
Radiation protec ...
By the university
University of Gothenburg

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view