A method for the intravital measurement of interspinous kinematics.

Kaigle Holm, Allison, 1964 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för ortopedi,Institute of Surgical Sciences, Department of Orthopaedics
Pope, M H (författare)
Fleming, B C (författare)
visa fler...
Hansson, Tommy H., 1943 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för ortopedi,Institute of Surgical Sciences, Department of Orthopaedics
visa färre...
 (creator_code:org_t)
1992
1992
Engelska.
Ingår i: Journal of biomechanics. - 0021-9290. ; 25:4, s. 451-6
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A novel non-radiographic technique for objectively quantifying quasi-static or dynamic intervertebral motion of a spinal motion segment in vivo in human subjects is presented here. The intervertebral motion device (IMD) is an instrumented linkage transducer system which can continuously measure over time two-dimensional sagittal plane rigid-body motion. Three custom-built omega-shaped displacement transducers are utilized. The IMD is rigidly fixed to the spinous processes of the lumbar motion segment by means of two intraosseous pins. Knowing the mechanoelectrical behavior and geometric configuration of the IMD, the relative spatial motion between the vertebral bodies can be resolved into sagittal rotation, axial translation, and anterior-posterior shear translation. Static calibrations of the IMD in the ranges of +/- 4 degrees rotation and +/- 4 mm translation determined the absolute maximum errors to be 0.2 degree and 0.07 mm for rotation and translation measurements, respectively, with corresponding variances of 0.1 degrees and 0.03 mm. For use in the vibration environment, negligible motion artifact content was detected in the IMD output signals when excited at discrete frequencies of 5.0 and 8.0 Hz. The first natural frequency of the IMD, specific for this design, was measured at 16.25 Hz. This technique may be used to study in vivo the spinal kinematics in healthy lumbar motion segments and in patients suspected of having segmental instability, and can perhaps be of clinical diagnostic significance.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Nyckelord

Bone Nails
Calibration
Electrodiagnosis
instrumentation
Equipment Design
External Fixators
Humans
Lumbar Vertebrae
physiology
Models
Biological
Movement
Rotation
Stainless Steel
Transducers

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Kaigle Holm, All ...
Pope, M H
Fleming, B C
Hansson, Tommy H ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kirurgi
Artiklar i publikationen
Journal of biome ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy