Principal component analysis: A novel analysis to evaluate the characteristics of osseointegration of different implant surfaces

Jimbo, Ryo, 1979 (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
Fernandez-Rodriguez, Julia, 1965 (author)
Gothenburg University,Göteborgs universitet,Core Facilities, Centre for Cellular Imaging,Core Facilities, Centre for Cellular Imaging
Sul, Young-Taeg, 1960 (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
show more...
Johansson, Carina B., 1955 (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institutionen för odontologi,Institute of Clinical Sciences, Department of Biomaterials,Institute of Odontology
show less...
 (creator_code:org_t)
2011
2011
English.
In: Implant Dentistry. - 1056-6163. ; 20:5, s. 364-368
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Objective: To apply a new statistical method (principle component analysis; PCA) to evaluate osseointegration. Materials and Methods: Two different commercially available implants were selected for the study. Twenty implants, 10 of each type, were placed in the rabbit tibiae (n = 10). The fluorochromes (FLCs) alizarin complexone and calcein green were administered after 20 days and 4 days before sacrifice for labeling. On the day of implantation and retrieval (6 weeks), implant stability was measured with a resonance frequency analyzer (RFA). The retrieved samples were ground sectioned for histomorphometric and FLC quantification. The collected data were analyzed by a PCA software program (Qlucore Omics Explorer, Lund, Sweden) to explore and determine the correlation between different study variables and to analyze the differences between different implants. Results: The RFA presented no significant differences at either time point. The bone-to-implant contact was significantly higher for the TiUnite (NobelBiocare, Gothenburg, Sweden); however, the bone area and FLC quantification showed higher values for the Osseotite (3i Implant Innovation, FL). Consistent with these results, the PCA indicated a strong correlation between TiUnite and high bone-to-implant contact values and between Osseotite and high bone area and FLC values. No correlation between RFA and the biological responses were found. Conclusion: The application of the PCA analysis may help interpret and correlate results obtained from numerous evaluations.

Subject headings

NATURVETENSKAP  -- Biologi (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Jimbo, Ryo, 1979
Fernandez-Rodrig ...
Sul, Young-Taeg, ...
Johansson, Carin ...
About the subject
NATURAL SCIENCES
NATURAL SCIENCES
and Biological Scien ...
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Dentistry
Articles in the publication
Implant Dentistr ...
By the university
University of Gothenburg

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view