SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:gup.ub.gu.se/208105"
 

Search: onr:"swepub:oai:gup.ub.gu.se/208105" > Calibrators for Cli...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Calibrators for Clinical Measurements of Phosphorylated H2AX in Patient Cells by Flow Cytometry

Muslimovic, Aida (author)
Gothenburg University,Göteborgs universitet,Institutionen för biomedicin, avdelningen för klinisk kemi och transfusionsmedicin,Institute of Biomedicine, Department of Clinical Chemistry and Transfusion Medicine
Johansson, Pegah, 1978 (author)
Gothenburg University,Göteborgs universitet,Institutionen för biomedicin, avdelningen för klinisk kemi och transfusionsmedicin,Institute of Biomedicine, Department of Clinical Chemistry and Transfusion Medicine
Rüetschi, Ulla, 1962 (author)
Gothenburg University,Göteborgs universitet,Institutionen för biomedicin, avdelningen för klinisk kemi och transfusionsmedicin,Institute of Biomedicine, Department of Clinical Chemistry and Transfusion Medicine
show more...
Hammarsten, Ola (author)
Gothenburg University,Göteborgs universitet,Institutionen för biomedicin, avdelningen för klinisk kemi och transfusionsmedicin,Institute of Biomedicine, Department of Clinical Chemistry and Transfusion Medicine
show less...
 (creator_code:org_t)
Bentham Science Publishers Ltd. 2012
2012
English.
In: The Open Clinical Chemistry Journal. - : Bentham Science Publishers Ltd.. - 2588-7785 .- 1874-2416. ; 5:1, s. 33-39
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Abstract: Agents that induce DNA double-strand breaks (DSBs), such as ionizing radiation, are frequently used in cancer therapy. H2AX is rapidly phosphorylated in response to DSBs and serves as a way to measure the extent of DSBs induced in patient cells. We have previously reported a flow cytometry-based method for measuring H2AX phosphorylation in pa-tient cells undergoing radiotherapy. To be able to implement measurement of H2AX phosphorylation in clinical practice, we have characterized calibrators for the flow cytometry analysis based on phosphopeptide-coated beads and fixed cells. The calibrator beads and fixed cells lost less than 11% of the signal after storage for 40 days under optimal conditions and were able to correct for day-to-day variation in method performance.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Klinisk laboratoriemedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Clinical Laboratory Medicine (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)

Keyword

H2AX
flow cytometry

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Muslimovic, Aida
Johansson, Pegah ...
Rüetschi, Ulla, ...
Hammarsten, Ola
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Clinical Laborat ...
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Cancer and Oncol ...
Articles in the publication
The Open Clinica ...
By the university
University of Gothenburg

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view