SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:gup.ub.gu.se/234496"
 

Search: onr:"swepub:oai:gup.ub.gu.se/234496" > THE VALIDITY OF USI...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

THE VALIDITY OF USING ROC SOFTWARE FOR ANALYSING VISUAL GRADING CHARACTERISTICS DATA: AN INVESTIGATION BASED ON THE NOVEL SOFTWARE VGC ANALYZER

Hansson, Jonny (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Månsson, Lars Gunnar, 1951 (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Båth, Magnus, 1974 (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
 (creator_code:org_t)
2016-03-14
2016
English.
In: Radiation protection dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 169:1-4, s. 54-59
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The purpose of the present work was to investigate the validity of using single-reader-adapted receiver operating characteristics (ROC) software for analysis of visual grading characteristics (VGC) data. VGC data from four published VGC studies on optimisation of X-ray examinations, previously analysed using ROCFIT, were reanalysed using a recently developed software dedicated to VGC analysis (VGC Analyzer), and the outcomes [the mean and 95 % confidence interval (CI) of the area under the VGC curve (AUCVGC) and the p-value] were compared. The studies included both paired and non-paired data and were reanalysed both for the fixed-reader and the random-reader situations. The results showed good agreement between the softwares for the mean AUCVGC. For non-paired data, wider CIs were obtained with VGC Analyzer than previously reported, whereas for paired data, the previously reported CIs were similar or even broader. Similar observations were made for the p-values. The results indicate that the use of single-reader-adapted ROC software such as ROCFIT for analysing non-paired VGC data may lead to an increased risk of committing Type I errors, especially in the random-reader situation. On the other hand, the use of ROC software for analysis of paired VGC data may lead to an increased risk of committing Type II errors, especially in the fixed-reader situation.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Hansson, Jonny
Månsson, Lars Gu ...
Båth, Magnus, 19 ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
Radiation protec ...
By the university
University of Gothenburg

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view