SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:gup.ub.gu.se/260099"
 

Search: onr:"swepub:oai:gup.ub.gu.se/260099" > Generating ActiGrap...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Generating ActiGraph Counts from Raw Acceleration Recorded by an Alternative Monitor

Brond, J. C. (author)
Andersen, L. B. (author)
Arvidsson, Daniel, 1974 (author)
Gothenburg University,Göteborgs universitet,Centrum för hälsa och prestationsutveckling,Institutionen för kost- och idrottsvetenskap,Center for Health and Performance,Department of Food and Nutrition, and Sport Science
 (creator_code:org_t)
Ovid Technologies (Wolters Kluwer Health), 2017
2017
English.
In: Medicine and Science in Sports and Exercise. - : Ovid Technologies (Wolters Kluwer Health). - 0195-9131. ; 49:11, s. 2351-2360
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Purpose: This study aimed to implement an aggregation method in Matlab for generating ActiGraph counts from raw acceleration recorded with an alternative accelerometer device and to investigate the validity of the method. Methods: The aggregation method, including the frequency band-pass filter, was implemented and optimized based on standardized sinusoidal acceleration signals generated in Matlab and processed in the ActiLife software. Evaluating the validity of the aggregation method was approached using a mechanical setup and with a 24-h free-living recording using a convenient sample of nine subjects. Counts generated with the aggregation method applied to Axivity AX3 raw acceleration data were compared with counts generated with ActiLife from ActiGraph GT3X+ data. Results: An optimal band-pass filter was fitted resulting in a root-mean-square error of 25.7 counts per 10 s and mean absolute error of 15.0 counts per second across the full frequency range. The mechanical evaluation of the proposed aggregation method resulted in an absolute mean +/- SD difference of -0.11 +/- 0.97 counts per 10 s across all rotational frequencies compared with the original ActiGraph method. Applying the aggregation method to the 24-h free-living recordings resulted in an epoch level bias ranging from -16.2 to 0.9 counts per 10 s, a relative difference in the averaged physical activity (counts per minute) ranging from -0.5% to 4.7% with a group mean +/- SD of 2.2% +/- 1.7%, and a Cohen' s kappa of 0.945, indicating almost a perfect agreement in the intensity classification. Conclusion: The proposed band-pass filter and aggregation method is highly valid for generating ActiGraph counts from raw acceleration data recorded with alternative devices. It would facilitate comparability between studies using different devices collecting raw acceleration data.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences (hsv//eng)

Keyword

gt3x
physical activity
filtering
algorithms
validation
physical-activity
observer agreement
accelerometer data
Sport Sciences

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Brond, J. C.
Andersen, L. B.
Arvidsson, Danie ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Health Sciences
Articles in the publication
Medicine and Sci ...
By the university
University of Gothenburg

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view