SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:gup.ub.gu.se/283377"
 

Search: onr:"swepub:oai:gup.ub.gu.se/283377" > Adherence to oxygen...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Adherence to oxygen saturation targets increased in preterm infants when a higher target range and tighter alarm limits were introduced

Klevebro, S. (author)
Karolinska Institutet
Hamar, U. (author)
Karolinska Inst, Inst Environm Med, Unit Biostat, Stockholm, Sweden
Holmström, Gerd, 1951- (author)
Uppsala universitet,Söderberg: Oftalmiatrik
show more...
Bottai, M. (author)
Karolinska Institutet
Hellström, Ann, 1959 (author)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi,Institute of Neuroscience and Physiology,Univ Gothenburg, Sahlgrenska Acad, Inst Neurosci & Physiol, Dept Ophthalmol, Gothenburg, Sweden
Hallberg, B. (author)
Karolinska Institutet
show less...
 (creator_code:org_t)
2019-04-25
2019
English.
In: Acta Paediatrica. - : Wiley. - 0803-5253 .- 1651-2227. ; 108:9, s. 1584-1589
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Aim European consensus guidelines published in May 2013 recommended a target peripheral capillary oxygen saturation (SpO(2)) range of 90-95% for preterm infants. These were incorporated into guidelines at the Karolinska University Hospital, Sweden, in November 2013. This study compared clinical practice before and after those local guidelines. Methods We included infants who were born between 23 + 0 and 30 + 6 weeks from January 1, 2013 to December, 31 2015 and received intensive care in two Karolinska units. The lower saturation target of 88-92% and alarm limits of 85-95% used before November 2013 were compared to the new higher saturation target of 90-95% and alarm limits of 89-96%. Results Data from 399 infants were analysed. The mean SpO(2) was 92.4% with the higher target (n = 301) and 91.1% with the lower target (n = 98). Using the higher instead of lower target meant that the SpO(2) was within the prescribed target range more frequently (51% versus 30%) and the proportion of time with SpO(2) >95% was increased by 9% (95% confidence interval 7-11%, p < 0.001). Conclusion The higher saturation target and tighter alarm limits led to higher mean oxygen saturation, increased adherence to the target and increased time with hyperoxaemia.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Pediatrik (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Pediatrics (hsv//eng)

Keyword

Oxygenation
Preterm infants
Pulse oximetry
Retinopathy of prematurity
Saturation target
european consensus guidelines
respiratory-distress-syndrome
birth-weight infants
retinopathy
prematurity
management
Pediatrics
Oxygenation

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view