Search: onr:"swepub:oai:gup.ub.gu.se/300299" >
The reliability, re...
-
Carmont, Michael R,1972Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
(author)
The reliability, reproducibility and utilization of the radiographic Achilles Tendon Loading Angle in the management of Achilles Tendon rupture.
- Article/chapterEnglish2021
Publisher, publication year, extent ...
Numbers
-
LIBRIS-ID:oai:gup.ub.gu.se/300299
-
https://gup.ub.gu.se/publication/300299URI
-
https://doi.org/10.1016/j.fas.2020.09.013DOI
Supplementary language notes
Part of subdatabase
Classification
-
Subject category:ref swepub-contenttype
-
Subject category:art swepub-publicationtype
Notes
-
During management of Achilles tendon rupture, determination of tendon-end approximation, either clinically or by ultrasound is difficult, following brace application of during loading. The Radiographic Achilles Tendon Loading Angle (RadATLA) is proposed as a method of measuring ankle position whilst loading in a brace during the management of Achilles tendon rupture. This study aims to determine the reliability and reproducibility of the RadATLA.A loaded true lateral ankle radiograph including the fifth metatarsal head was taken when wearing a brace at the 6-week time point in 18 patients (19 ankles). following Achilles tendon repair or reconstruction. The RadATLA was compared with the Tibio-talar angle, other radiographic and clinical measures used to quantify foot and ankle position during the first 6 weeks of early rehabilitation in a resting position and during loading.The intra-rater reliability of both angles was found to be good (>0.8). The RadATLA was found to have an excellent intra-rater reliability with Intra-class correlation of (ICC) 0.992-0.996 (95%CI 0.889-0.999), standard error of the measurement (SEM) 1.03-3.65 and Minimal Detectable Change (MDC) 2.86-10.12. The inter-rater reliability was good with ICC of 0.798-0.969 (95%CI-0.03 to 0.964), SEM 2.9-7.6, and MDC 8.1-20.9. The RadATLA loaded at 6 weeks in all patients was at mean (SD) (range) 41.9˚ (16.5), (18.5-75.9). There was a significant difference between the patients in the Repair group compared with patients in the Reconstruction group both in RadATLA loaded at 6 weeks: 35.6˚ (11.2), (18.5-56.5) versus 55.5˚ (19), (20-75.9), (p = 0.01). The amount loaded in all patients was at mean (SD) (range) 29.2Kg (17.7), (2-56) and the percentage Body Weight was 30.7% (19), (2.1-63.2). There were no differences between the groups neither in amount loaded nor in percentage Body weight (p = 0.614-0.651).The RadATLA is a reliable and reproducible angle and can be used to determine the position of the ankle, when loaded in a brace during rehabilitation following Achilles tendon rupture.
Subject headings and genre
Added entries (persons, corporate bodies, meetings, titles ...)
-
Brorsson, Annelie,1963Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics(Swepub:gu)xbrora
(author)
-
Barfod, Kristoffer Weisskirchner
(author)
-
Ginder, Laurence
(author)
-
Littlehales, Julie
(author)
-
Karlsson, Jón,1953Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics(Swepub:gu)xkajon
(author)
-
Nilsson-Helander, Katarina,1957Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics(Swepub:gu)xnkata
(author)
-
Göteborgs universitetInstitutionen för kliniska vetenskaper, Avdelningen för ortopedi
(creator_code:org_t)
Related titles
-
In:Foot and ankle surgery : official journal of the European Society of Foot and Ankle Surgeons: Elsevier BV27:7, s. 760-7661460-9584
-
In:Foot and Ankle Surgery: Elsevier BV27:7, s. 760-7661268-7731
Internet link
Find in a library
To the university's database